Care And Cleaning; Technical Data - VOLTCRAFT VC-655 BT Operating Instructions Manual

55,000 count bench type dmm datalogger
Hide thumbs Also See for VC-655 BT:
Table of Contents

Advertisement

Available languages

Available languages

• Measurement CAT III applies to protect against transients in equipment in fixed
equipment installations, such as distribution panels, feeders and short branch
circuits, and lighting systems in large buildings.
• Measurement CAT IV applies to measurements performed at the source of the
low-voltage installation. Examples are electricity meters and measurements on
primary over current protection devices and ripple control units.

Care and cleaning

• Disconnect the product from the mains before cleaning.
• Do not use any aggressive cleaning agents, rubbing alcohol, or other chemical solutions as
they can cause damage to the housing and functioning of the product.
• Clean the product with a dry, fibre-free cloth.
Disposal
Electronic devices are recyclable waste and must not be disposed of in household
waste. At the end of its service life, dispose of the product in accordance with ap-
plicable regulatory guidelines.
You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical data

AC current .................................... 500 uA/5000 uA/50 mA/500 mA/5 A/10 A,
Accuracy: ±(0.5 %+20 digits)
DC current .................................... 500 uA/5000 uA/50 mA/500 mA/5 A/10 A,
Accuracy: ±(0.15 %+10 digits)
AC voltage .................................... 500 mV/5 V/50 V/500 V/750 V,
Accuracy: ±(0.5 %+30 digits)
50 mV/500 mV/5 V/50 V/500 V/1000 V,
Accuracy: ±(0.05 %+5 digits)
Capacitance .................................. 50 nF – 500 uF: ±(2.5 % + 10 digits)
5 mF – 50 mF: ±(5 % + 10 digits)
Resistance .................................... 500.00 Ω / 5.0000 kΩ / 50.000 kΩ / 500.00 kΩ /
5.0000 MΩ / 50.000 MΩ, Accuracy: ±(0.15%+5 digits)
Temperature measurement .......... Supports ITS90 K type and PT100 temperature sensors
Display .......................................... 3.7 inch 480 x 320 pixel LCD
Resolutions ................................... Max. 4 (1/2) digits, 55,000 counts
Reading rate ................................. Max. 64 readings per seconds
Measurement bandwidth .............. 20 Hz – 1 kHz
Interface ........................................ USB-B 2.0
System requirements .................... Windows Vista 32 bit, Windows 7 (32/64 bit) or later
Operating conditions ..................... 0 °C to +40 °C
<75 % RH for 0 °C to +30 °C
<50 % RH for +30 °C to +40 °C
0-2000 m altitude
Storage conditions ........................ -10 °C to +50 °C
<75 % RH for -10 °C to +30 °C
<50 % RH for +30 °C to +50 °C
Dimensions (W x H x D) ............... 200 x 92 x 148 mm
Weight .......................................... 450 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights in-
cluding translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication
represent the technical status at the time of printing.
Copyright 2021 by Conrad Electronic SE.
*2357060_v2_0621_02_DS_ss_4L_(1)