WSE 81 PLUS and WSE EVO

SYSTEM DESCRIPTION

The IR light curtain series WSE 81 PLUS and WSE EVO consist of a transmitter detector (TX) and a receiver detector
(RX), they can be installed on the car door dynamically or statically on the doorsill. The detector system provides an IR
light curtain with a crisscross beam pattern in the area of the car entrance. If any beam is blocked, the output is
triggered and switches to reopen the doors again.

INSTALLATION

The systems can be installed either on the moving
doors or statically in a position on the end of the
door sill.
(a) Dynamic Installation
The system is mounted on the car doors using the
dynamic fixing kit provided.
1. Position each detector on the car door. Check the
detectors will be:
·
fitted approximately 5mm above the sill
·
aligned level and straight with each other
2. Screw the detectors to the door using the No
6x16 self-drilling screws provided.
3. Secure the cables with the P-clips and No
8x12mm self-tapping screws provided. Ensure
the cables are securely held, there are no tight
bends and they are no stressed or stretched as
the doors move.
(b) Static Installation
Please be aware of the maximum range of the
systems when you are using static installation.
We reserve the right to make alterations with respect to the specifications and figures in this manual.
WITTUR Austria GmbH
Sowitschstrasse 1
Tel +43 (0) 7482/42542-0
http://www.wittur.com
Emphasis, translation and duplication in each form - also in excerpts - needs the written
Authorization of the WITTUR Austria Ltd.
-------------------------
Page PM.9.002886.EN.001
Date
P/No:
A-3270 Scheibbs, Austria
Fax +43 (0) 7482/42542-232
E-mail:
info.at@wittur.com
-------------------------
08.02.2016
500 852GB/Version B

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WSE 81 PLUS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WITTUR WSE 81 PLUS Series

  • Page 1 Emphasis, translation and duplication in each form - also in excerpts - needs the written Authorization of the WITTUR Austria Ltd. We reserve the right to make alterations with respect to the specifications and figures in this manual. -------------------------...
  • Page 2 Installation Sheet Page PM.9.002886.EN.002 WSE 81 PLUS and WSE EVO Date 08.02.2016 P/No: 500 852GB/Version 1 SYSTEM CONNECTION The system can be directly connected to the lift controller or door operator. In such cases the opto-relay output inside the RX detector drives the "door re-open" circuit on the lift. Warning –...
  • Page 3 Installation Sheet Page PM.9.002886.EN.003 WSE 81 PLUS and WSE EVO Date 08.02.2016 P/No: 500 852GB/Version 1 Figure 3 Connection diagramm ECO+/MIDI+/SUPRA door controller black yellow black If you are using the WLS blue power supply unit: PLEASE USE TAPE FOR INSULATING THE GREEN WIRE TO AVOID A SHORT CIRCUIT IN THE WLS...
  • Page 4 Installation Sheet Page PM.9.002886.EN.004 WSE 81 PLUS and WSE EVO Date 08.02.2016 P/No: 500 852GB/Version 1 RX Cable connection WLS Switch +12V Setting Green/Black Blue Yellow Supply- voltage Door Re-open circuit TX CABLE TO LIFT CONTROLLER OR 0V - BLACK DOOR OPEN CIRCUIT +12V - RED Please note: The preferred setting of...
  • Page 5 Installation Sheet Page PM.9.002886.EN.005 WSE 81 PLUS and WSE EVO Date 08.02.2016 P/No: 500 852GB/Version 1 Auto beam disabling function The detectors of the WSE 81 PLUS and WSE EVO Series are supplied with learning mode (automatic beam disabling) enabled the first time the detectors are switched on. To switch off beams - Block those beams that are (or will be) disabled using opaque tape.
  • Page 6 Installation Sheet Page PM.10.002886.EN.006 WSE 81 PLUS and WSE EVO Date 08.02.2016 P/No: 500 852GB/Version 1 Technical Details – Model WSE 81 PLUS Technical Details – Model WSE EVO Dimension 10 mm x 33,5 mm x 2005 mm 10 mm x 33,5 mm x 2005 mm Connection cable 4 m on transmitter TX and receiver RX 4 m on transmitter TX and receiver RX...

This manual is also suitable for:

Wse evo series

Table of Contents