11 Service Position
Note: For description of the disassembly procedures, see
the Section 10.
11.1. Checking of Panel P.C.B.
Step 1 Remove Top Cabinet.
Step 2 Remove Front Panel Unit.
Step 3 Position the Front Panel Unit as shown.
Step 4 Attach 10P FFC at connector (FP3002) on Main P.C.B..
Step 5 Attach 30P FFC at a connector (CN2004) on the Main
P.C.B..
Step 6 Attach 5P Cable Wire at connector (CN2001) on Main
P.C.B..
Step 7 Panel P.C.B. can be check at diagram shown.
11.2. Checking of Main P.C.B. (Side
A)
Step 1 Remove Top Cabinet.
Step 2 Main P.C.B. (Side A) can be check at diagram shown.
11.3. Checking of Main P.C.B. (Side
B)
Step 1 Remove Top Cabinet.
Step 2 Remove Front Panel Unit.
Step 3 Remove Main P.C.B..
Step 4 Place the Main P.C.B. on an insulated material.
Step 5 Remove 4 screws (for AKX77) and 3 screws (for
AKX57).
Note:
Below 3 screws are for model AKX57.
38