Next is the setting for minimum pump speed during the start.
Only adjust this if the combustion is slow to get going.
100 is the usual default and it increments at 25 a time with + and –
buttons. Too high a setting will make flames at the starting. Leave it
as factory set.
Press the > button to continue
Now we come to Glow Plug Power. It should be set as low as possible
Default is 5.8 / 6.2v
to still function.
Already adjusted and tested at factory. Only adjust this +/- if the
glowplug is not able to ignite the fuel.
This could be seen by a hissing sound at the start and white smoke
from exhaust. In this case, adjust upwards by 0.2v Having too high a
setting shortens the life of the glowplug.
There are no more functions to adjust in this branch so exit by press-
ing > until you return to the opening screen.
Press the > button twice to get back to the main navigation Menu.
Press the button under the INFO option
Timer screen.
TimerServ shows the runtime on the engine since last maintenance
service. Last shows the duration of the last run in secs, and (Cy) the
total number of times the engine has reached idle on a start.
RX Errors screen
This shows any time when the receiver signal has been lost or outside
the normal range, glitches etc, during the last run.
Normally shows 0 or low number. Is reset each new start.