FUNCTIONAL DESCRIPTION

Figure 1 names the major components of the
HAUSSMANN XPERT 2 in 1 nailer:
A. Deflector
B. Body
C. Quick release
D. Magazine
E. Fixed latch
F. Air plug
G. Depth control valve
H. Trigger

OPERATING PROCEDURES

SETUP
AIR SOURCE
The HAUSSMANN XPERT nailer is designed to operate on clean, dry, compressed
air, regulated at 70-110 PSI. The preferred system would include a filter, a pressure
regulator, and an automatic oiler located as close to the tool as possible. Within 15
feet (5 m) is ideal. Do not use bottled air or gases. Please see below:
Nailer
All compressed air contains moisture and other contaminants that can harm the
internal components of the tool. An air line filter will remove most of these and
significantly prolong the life of the tool. Ensure the in-line oiler has sufficient oil. If
an in-line oiler is not available, place 2 drops of oil into the tool's air inlet at the
beginning of each workday. More than this will be expelled from the tool's exhaust
during firing.
Air fitting: The nailer should be equipped with a 1/4" NPT male quick connector.
To prevent accidental cycling even though disconnected, the tool must always be
connected to the air supply in such a way that all air pressure in it is released
when the coupling is disconnected.
20
PNT138-R
Air hose
Quick coupling
A
B
C
Regulator
Oiler
Filter
F
H
E
D
G
Fig.1
Air connector
Fig.2
Fig.3

Hide quick links:

Advertisement

loading

This manual is also suitable for:

68125013