ELETTRO CF s.r.l.
3.3.2 - Power source powered, led (A) lit, fan (9) stopped.
FAN (9) TEST.
Fan (9) fast-on terminals = 230 Vac, approximately, after closing switch (24).
Make sure that there are no mechanical impediments blocking the fan (9).
Replace the fan (9).
Check the wiring between fan (9) and connector J2 and J3 on power board (8).
Check the presence of 230V approx. on switch (24).
Check the switch (24) and replace if defective.
3.3.3 – Power source powered, the signals do not indicate correct values.
LED (D) steady lit, insufficient air.
-
Carry out the compressor test, see par. 3.3.5.
LED (C) steady lit, thermal protection.
-
Check the working conditions of thermostat and replace if defective.
-
Replace the power board (8).
LED (B) steady lit, power source blocked.
This indicator indicates that the power source is in an analysis phase, in the first 5 seconds
after closing the switch (24), or, thereafter, is blocked due to a hazardous condition. Check
the value of supply voltage.
If previous steps have not solved the problem, replace the power board (8).