ICT2XX AND IWL25X USB SOFTWARE UPGRADE
IMPORTANT!!
Please note this document has been updated to reflect changes for the 16mb iCT220 terminals in
the release version of 346 R2. Critical changes to the document are highlighted in yellow
This document describes the process for updating each of the following terminal types along with
the relevant software versions. Please read this document carefully and apply whichever method is
the correct one for the terminal you are upgrading.
iCT250
iCT220
iWL25x
PLEASE NOTE: If the terminal has 1536-bit keys - DO NOT UPGRADE as it will eventually cease to
operate.
THE TERMINAL WILL NEED TO BE RETURNED TO SKYZER FOR NEW 2048-bit KEYS
Skyzer Technologies is currently undertaking a process of updating the software on our terminal
fleet to the latest 2018.1 (SHA-2) version 341 R1 Paymark software. This is for terminals that are
unable to dial in to our TMS and also includes iWL255 terminals with Paymark SIM cards. The USB
flash drives that have been issued will need to up update to the latest 2018.1 (SHA-2) version. This
will contain the Eftpos application that needs to be loaded into the terminals by following the
instructions below.
Contents
ICT2XX AND IWL25X USB SOFTWARE UPGRADE PROCESS ..................................................................... 0
1
Check for Pending Transactions ...................................................................................................... 1
2
Checking the RAM Memory for iCT250 Terminal ............................................................................ 2
3
Delete Secondary Application on iCT250 for 16MB Terminal ONLY ............................................... 2
4
iCT250 Terminal Software Upgrade ................................................................................................ 3
5
Checking the RAM Memory for iCT220 Terminal ............................................................................ 5
6
Changing Memory Size on iCT220 for 16MB Terminal ONLY .......................................................... 5
7
Delete Secondary Application on iCT220 for 16MB Terminal ONLY ............................................... 6
8
iCT220 Terminal Software Upgrade ................................................................................................ 6
9
iCT220 Terminal Upgraded to PTS2018.1 (SHA-2) .......................................................................... 8
10
iWL25X Terminal Software Upgrade ........................................................................................... 9
PROCESS PTS2018.1 V346 R2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iCT250 and is the answer not in the manual?

Questions and answers

Summary of Contents for Skyzer iCT250

  • Page 1: Table Of Contents

    THE TERMINAL WILL NEED TO BE RETURNED TO SKYZER FOR NEW 2048-bit KEYS Skyzer Technologies is currently undertaking a process of updating the software on our terminal fleet to the latest 2018.1 (SHA-2) version 341 R1 Paymark software. This is for terminals that are unable to dial in to our TMS and also includes iWL255 terminals with Paymark SIM cards.
  • Page 2: Check For Pending Transactions

    If pending transactions are present during an upgrade the terminal will automatically deactivate and will need to be returned to Skyzer Service Centre. Please perform the steps below to determine if there are any pending transactions in the terminal prior to upgrading.
  • Page 3: Checking The Ram Memory For Ict250 Terminal

    Page 2 of 11 Checking the RAM Memory for iCT250 Terminal Additionally, we have a separate Stage 3 package for iCT250 16MB RAM terminals. If you have an iCT250 terminal with 16MB RAM, load the CONF_STAGE3 ICT250-16MB package after completing Stage 1 and 2.
  • Page 4: Ict250 Terminal Software Upgrade

    Lift the cover to the rear to remove it, as shown by arrows on the figure. STEP 2: PLUG IN THE USB FLASH DRIVE Once you have opened the cover, plug in the USB flash drive provided by Skyzer Technologies into the USB Host port as shown below.
  • Page 5 3. After software is successfully activated, terminal will automatically restart. Repeat the above steps again to load CONF-STAGE2, 3 and 4. (NOTE: If you have an iCT250 with 16MB RAM, please on stage 3 load the stage 3–iCT250 16MB package and ensure that the secondary applications are deleted from the terminal) 4.
  • Page 6: Checking The Ram Memory For Ict220 Terminal

    Page 5 of 11 Checking the RAM Memory for iCT220 Terminal Additionally, we now have a separate Stage 1 and Stage 3 package for iCT220 16MB RAM terminals. If you have an iCT220 terminal with 16MB RAM, load the CONF_STAGE1 ICT220-16MB and CONF_STAGE3 ICT220-16MB package.
  • Page 7: Delete Secondary Application On Ict220 For 16Mb Terminal Only

    Page 6 of 11 Delete Secondary Application on iCT220 for 16MB Terminal ONLY The following application will need to be deleted from the iCT220 16MB terminal prior to upgrading software through USB flash drive. NOTE: BE VERY CAREFUL WHEN DELETING THE APPLICATION. CHECK TO ENSURE YOU HAVE SELECTED THE CORRECT APPLICATION TO DELETE AND THEN PRESS ENTER.
  • Page 8 Page 7 of 11 STEP 2: PLUG IN THE USB FLASH DRIVE Once you have opened the cover, plug in the USB flash drive provided by Skyzer Technologies into the USB Host port as shown below. USB Host Port STEP 3: GETTING INTO USB MASS STORAGE MODE Once the USB flash drive is plugged in, turn the terminal back on by plugging the power cable into the multicom adaptor.
  • Page 9: Ict220 Terminal Upgraded To Pts2018.1 (Sha-2)

    Page 8 of 11 STEP 6: CLOSING THE CABLE COVER o To close the cover, start by inserting the clips of the cover in their housing respectively first, as shown on the figure below, and close the cover. Once the cover has been returned the terminal can then be powered back on. iCT220 Terminal Upgraded to PTS2018.1 (SHA-2) Once an iCT220 terminal has been upgraded to PTS2018.1 (SHA-2) software via USB flash drive, the following terminal functions will be deactivated.