Page 3
Thanks for selecting the Donper USA D600 Soft Serve Machine. The purpose of this manual is to provide you with the product specifications and our recommendations for effective and normal operation of this machine in order to ensure and guarantee it’s service life.
Page 4
Model Size (inch) Voltage Power Net Weight Refrigerant 230 lbs D600 33 x 25 x 34 115v 2300w R404a (105 kg)
Page 5
It is recommended that the environmental temperature shall not exceed 32˚C. 3. When lifting the D600, be sure to slide your hands underneath the ma- chine so that the base of the machine is resting on top of your hands. Do...
Page 6
When your Donper USA D600 is delivered, it will arrive in a crate. The first thing you will need to do is remove the machine from the crate. 1. Place the crate on a flat surface. 2. Remove the lid from the crate by using a flathead screwdriver to flip up the tabs on all four sides of the lid that attach the lid to the sides of the crate.
Page 7
The D600 comes set in its recommended factory settings. Once you have your machine set up, flip the main power switch, located below the control panel, into the on position. 1. Pour mix into the hopper and be sure not to overfill past the maximum capacity line.
Page 8
Firmness Setting on your D600. This setting can be adjusted while the machine is in “Ready Mode” or “Auto Mode”. 1. Press & Hold the “UP” or “DOWN” button on the control panel of the D600 until the word “SET” begins to flash on the display screen.
Page 9
The “HOPPER COOLING” switch is located under the control panel next to the “MAIN POWER” switch. To use this feature simply switch this from the off position to the on position. This feature is not a controlled function. When the switch is in the on position, the compressor is constantly cooling the hopper and it will not shut off unless the switch is manually placed into the off position.
Page 10
Cleaning up the D600 is simple. Once you have pressed the “STOP” button and you machine is now in “Ready” mode, simply follow the instructions below. 1. Press the “WASH” button on the display panel to activate the drive motor.
7. Next remove the faceplate and auger from the machine and clean. 8. Wipe down the inside of the hoppers and freezing cylinders with a soft cloth or sponge. 9. Once all parts have been cleaned, be sure to add Food Grade Lubricant to all of the rubber gaskets and seals;...
Page 12
If you have any questions, please feel free to contact u s toll free at (844) 366-7371 24610 Kingsland Blvd Katy, Texas 77494 www.donperusa.com...
Need help?
Do you have a question about the D600 and is the answer not in the manual?