Notification V8 Type
TYPE
Movement
System (0x09)
Synchronic
Clock (0x0B)
Time
Button
Emergency (0x0A)
Press
V1 Alarm
TYPE
Movement
0x09
Synchronic
0x09
Time
Button
0x0A
Press
Configuration - Synchronic Time Interval
Byte
1 ~ 127 (Set up from 16
Parameter 1
1
(Table 3)
(P.S.: This is the definition how long ZA1502-7 will contact
Gateway for having a synchronic information. The basic
interval time is 16 seconds, the synchronic time will be the
basic interval time by Parameter 1's value.)
EVENT
Heartbeat (0x05)
Timer Ended (0x02)
Contact Medical Service (0x03)
(Table 1)
VALUE
0xFF
0x00
0xFF
(Table 2)
Value
Default
4 (= 16 seconds x 4)
to 2032 seconds)
- 3 -
Operation
Notice: If you are installing the entire Z-Wave™ system for the first time, please
refer to the installation guide of Z-Wave™ Interface Controller and full charging the
ZA1502-7 before using..
1.
Green LED turns on while pressing
Quick press the button of ZA1502-7 5 times for showing the sensor's inclusion status.
2.
- Not Included : Red/Green LED flashing 5 times quickly.
- Included
: Red/Green LED flashing 1 second.
For "Inclusion" in (adding to) a network: Put the Z-Wave™ Interface Controller into
3.
"inclusion" mode, and following its instruction to add the ZA1502-7 to your controller.
To get in the "inclusion" mode, quick press the button of ZA1502-7 5 times for sending
the NIF, the Red/Green LED will flash 5 times quickly before the learning process for
showing the sensor has not been included. After sending NIF, Z-Wave will send the
auto inclusion, the Red/Green LED will flash 1 second after successful inclusion;
otherwise, ZA1502-7 will go to sleep after 30 seconds.
while the inclusion is proceeding.
For "Exclusion" from (removing from) a network: Put the Z-Wave™ Interface
4.
Controller into "exclusion" mode, and following its instruction to delete the ZA1502-7
from your controller. Quick press the button of ZA1502-7 5 times to be excluded,
the Red/Green LED will flash 5 times quickly after successful exclusion.
Note: All user and network settings will be cleared and the device reset to factory
defaults when the device is excluded.
5. Trigger Response:
- Movement: The sensor will send Notification Report (refer to Table 1 & 2) if it has
been moved.
- Synchronic Time: The sensor will send Notification Report (refer to Table 1 & 2)
and exceed the preset synchronic time (refer to Table 3).
- Button Press: Press the button of ZA1502-7 once for sending Notification Report
(refer to Table 1 & 2) if button has been pressed for any specific purpose.
6. Wake Up Notification:
Press the button of ZA1502-7 2 times will active the "Wake Up Mode" for receiving all
the command class from controller. The ZA1502-7 will go to sleep mode without
receiving any Z-Wave command till 10 seconds. It will proceed all the commands
after sending the "Wake Up Notification"
7. Auto Wake Up:
Use "Wake Up" command to set up the awaking interval and send the wake up
notification to controller. User can use "Wake_Up" command to change the auto
wake up interval from 10 minutes to 1 week, Interval increment is 200 seconds.
(Default Value: 24 hours.)
the button of ZA1502-7
.
The red LED will be flashing
- 4 -