Product Description and Specification:
Specification:
Protocol: Z-Wave™ (ZGM130S)
Frequency Range:
865
.
22
M H z
(ZA1502IN-7)
868
.
42
M H z
(ZA1502EU-7)
869
.
00
M H z
(ZA1502RU-7)
908
.
42
M H z
(ZA1502US-7)
916
.
00
M H z
(ZA1502IL-7)
919
~
923
M H z
(ZA1502KR-7)
919
.
80
M H z
(ZA1502HK-7)
922
~
926
M H z
(ZA1502JP-7)
921
.
42
M H z
(ZA1502BR-7)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -10°C~ 60°C (14°F ~140°F)
Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION_V4
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
COMMAND_CLASS_INDICATOR_V3
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_SECURITY
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
Movement
Notification V8
Type:
(Table 1)
Synchronic Time
Button Press
Movement
V1 Alarm:
(Table 2)
Synchronic Time
Button Press
Configuration
(Table 3)
Command Class:
Parameter 1
Remark:
1. This is the definition how soon ZA1502-7 will contact Gateway after a movement behavior for triggering the
device and having a synchronic information. The basic interval time is 16 seconds, the synchronic time will be
the basic interval time by Parameter 1's value.
2. The battery life will be shorter if the synchronic time is quicker.
Introduction
Thanks for choosing the Vision's wireless 2 in 1 Universal
Remote (ZA1502-7) of the home security device. This sensor
is a Z-Wave Plus™. enabled device (interoperable, two-way
RF mesh networking technology) and is fully compatible with
any Z-Wav enabled network and its security framework. Every mains
powered Z-Wave PLUS™ enabled device acts as a signal repeater and
multiple devices result in more possible transmission routes which helps
eliminate "RF dead-spots"
Z-Wave Plus™. enabled devices displaying the Z-Wave Plus™. logo can also
be used with it regardless of the manufacturer, and ours can also be used in
other manufacturer's Z-Wave Plus™. enabled networks. ZA1502-7 is an
Arrival sensor combines a unique button whose function can be defined as
one of below:
- Scene Control
- On/Off Control
When the device is secure included into Z-Wave network, above communica-
tion will be encrypted. ZA1502-7 supports SECURITY S0 / SECURITY S2
UNAUTHENTICATED / SECURITY S2 AUTHENTICATED.
Limited Warranty
Vision Guarantees that every wireless 2 in 1 Universal Remote is free from
physical defects in material and workmanship under normal use for one
year from the date of purchase. If the product proves defective during this
one-year warranty period, Vision will replace it free of charge. Vision does
not issue any refunds. This warranty is extended to the original end user
purchase only and is not transferable. This warranty does not apply to: (1)
damage to units caused by accident, dropping or abuse in handling, or any
negligent use; (2) units which have been subject to unauthorized repair,
taken apart, or otherwise modified; (3) units not used in accordance with
instruction; (4) damages exceeding the cost of the product; (5) transit
damage, initial installation costs, removal cost, or reinstallation cost. For
information on additional devices, please visit us at
www.visionsecurity.com.tw
Package Content
1pc ZA1502-7
1pc Operation manual
Z-Wave S2 Support Command Classes :
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION_V4
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
COMMAND_CLASS_INDICATOR_V3
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3
COMMAND_CLASS_NOTIFICATION_V8
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_VERSION_V3
COMMAND_CLASS_WAKE_UP_V2
TYPE
EVENT
System (0x09)
Heartbeat (0x05)
Clock (0x0B)
Timer Ended (0x02)
Emergency (0x0A)
Contact Medical Service (0x03)
TYPE
VALUE
0x09
0xFF
0x09
0x00
0x0A
0xFF
BYTE
VALUE
Default
1 ~ 127 (Set up from 16
1
4 (= 16 seconds x 4)
to 2032 seconds)
ZA 1502-7
V0
1091224
- Arm/Disarm
- Emergency Help
Installation & Operation Manual
2 in 1 Universal Remote
Z A 1 5 0 2 I N - 7
ZA1502EU-7
ZA1502RU-7
ZA1502US-7
Z A 1 5 0 2 I L - 7
ZA1502KR-7
ZA1502HK-7
ZA1502JP-7
ZA1502BR-7
Federal Communications Commission Statement
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
FCC Caution
"the user that changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate
the equipment."
FCC Statement in User's Manual (for calss B) FCC Section 15.105
"Federal Communications Commission (FCC) Statement"
This equipment has been tested and found to comply with the limits for a
class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interfer-
ence in a residential installation. This equipment generates uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
www.visionsecurity.com.tw

Advertisement

loading

Summary of Contents for Vision ZA1502IN-7

  • Page 1 However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Vision Guarantees that every wireless 2 in 1 Universal Remote is free from interference to radio or television reception, which can be determined by...
  • Page 2 Operation ZA 1502-7 Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to the installation guide of Z-Wave™ Interface Controller and full charging the ZA1502-7 before using. Button Green LED turns on while pressing the button of ZA1502-7. Quick press the button of ZA1502-7 5 times for showing the sensor’s inclusion status.

This manual is also suitable for:

Za1502eu-7Za1502ru-7Za1502us-7Za1502il-7Za1502kr-7Za1502hk-7 ... Show all