Module Connection; Outdoor Entrance Panel Module Consumption Table; Powered By Art. 1210/1210A; Powered By Additional Power Supply Unit Art. 1595 - Comelit Simplebus2 Ultra UT2010 Technical Manual

Audio module
Table of Contents

Advertisement

Module connection

On systems with Art. UT2010 and power supply unit Art. 1210/1210A, the maximum current available for the
outdoor entrance panel modules is 100 mA.
Calculate the total power consumption of the modules in your system configuration using the Consumption
table.
If the total power consumption exceeds 100 mA, connect a supplementary power supply unit (Art. 1595)
to the V+ and V- contacts of the outdoor entrance panel, as shown in the figure below (see
connections with separate power
A

powered by Art. 1210/1210A

UP
L

Outdoor entrance panel module consumption table

Code
UT9200
Call button modules
UT9240
Information module
UT9240M
Metal information module
UT9279M
Number keypad module
UT9310M
Magnetic induction module
UT9270
Touchscreen module
supply"). In any case, the total absorption must be lower than 500 mA.
L
B

powered by additional power supply unit Art. 1595

UP
L
L
V-
V+
Consumption (mA)
12.5
12.5
12.5
40
75
100
245
100
"UT2010
Relays disabled and audio or audio/
video module SE output used
With 1 bistable relay active
With 2 bistable relays active at the same
time
Always needs to be powered by
additional power supply unit Art. 1595
In systems with an outdoor entrance
panel consisting of 1 audio or audio/
video module, Touch module art.
UT9270 and up to 80 users, it is not
necessary to provide any additional
power supply.
For all other combinations, provide an
additional power supply unit art. 1595
J4
15

Advertisement

Table of Contents
loading

Table of Contents