Medical suction unit

Advertisement

SA 12 SA 14
SA 15 SA 16
Medical Suction Unit
Operating and Maintenance Manual
M.G. Electric (Colchester) Ltd
Altbarn Close, Colchester, Essex, CO4 9HY, United Kingdom
Tel: +44 (0) 1206 842244, Fax: +44 (0) 1206 845849
e-mail: sales@mgelectric.co.uk
www.mgeworldwide.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SAM 12 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for MGE UPS Systems SAM 12

  • Page 1 SA 12 SA 14 SA 15 SA 16 Medical Suction Unit Operating and Maintenance Manual M.G. Electric (Colchester) Ltd Altbarn Close, Colchester, Essex, CO4 9HY, United Kingdom Tel: +44 (0) 1206 842244, Fax: +44 (0) 1206 845849 e-mail: sales@mgelectric.co.uk www.mgeworldwide.com...
  • Page 2 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual Dear Customer, We take this opportunity to thank you for purchasing a SA Medical Suction Unit. Please read the operating instructions and listed precautions thoroughly before attempting to operate the unit. MG Electric manufactures its range in accordance with the requirements of BS EN ISO 9001 and BS EN ISO 13485 INDEX...
  • Page 3 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual Return of Medical Equipment Should you wish to return any equipment to MG Electric (Colchester) Limited (MGE), or one of our designated distributors, Health Service Guideline HSG (93) 26 Decontamination of equipment prior to inspection, service or repair) must be adhered to.
  • Page 4: Safety Instructions

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 1. SAFETY INSTRUCTIONS The safety of the patient and suction unit operator are the first priorities. It is therefore vital that the following precautions are strictly observed: WARNING!!! Never operate a SAM suction unit without an MGE filter capsule.
  • Page 5 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual Never operate a SA suction unit in the presence of flammable gas such as anaesthetic agents. This is an Explosion hazard! Ensure the power cable does not create a trip hazard or is subject to damage. The suction pumps may only be opened by qualified technical personnel.
  • Page 6: General Description

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 2. GENERAL DESCRIPTION SA 12 - General-purpose high vacuum medical suction unit, incorporating one collection container of 2L capacity. Designed for all medical procedures that require an adjustable high vacuum.
  • Page 7 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 3. INSTRUCTIONS FOR USE 3.1 Before Operating Unit BEFORE operating your new SA unit please read the following instructions carefully. Become thoroughly familiar with the operation and maintenance of the unit before using and note the information on the control panel and rear of the unit.
  • Page 8: Internal Filter

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual rings are autoclavable. However, the filter capsules are ‘Single Patient Use’ and must not be autoclaved. The external filter must be changed with every patient and renewed in accordance with the recommendations detailed in the ‘Daily Procedures’.
  • Page 9 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual Warning! The overflow valve may not operate fully against frothing. To reduce frothing anti-foam agent may be used. Warning! When replacing a full collection container, be aware of its weight and ensure handling the container is comfortable to avoid the possibility of spillage.
  • Page 10: Cleaning Procedure

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual • At the end of the procedure, the SA unit should remain switched on while the patient suction tubing is removed from the patient port and discarded. •...
  • Page 11: Long Term Storage

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 3.11 Transport The SA unit will be adequately boxed and protected to ensure no damage occurs during normal transportation of goods, providing the ambient conditions are within the following parameters: Temperature max +60°C min -20°C Humidity max +80% min +30% -20°C...
  • Page 12: Maintenance

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 4. MAINTENANCE Warning! Other than for routine daily procedures, any maintenance or repairs to MG Electric products must be carried out by fully trained and qualified engineers (EBME) or an authorized MG Electric dealer.
  • Page 13: Monthly Maintenance

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 4.2 Monthly Maintenance Carry out the daily maintenance procedure. • • Check the vacuum and the flow at the collection container top. With the collection container empty and the vacuum control valve set to maximum, •...
  • Page 14 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual • Replacing the Internal Hydrophobic Filter Check the internal wiring for ageing or wear. Replace with equivalent material and • terminations where necessary. • Examine the mains cable for wear or damage and replace if necessary using equivalent cable.
  • Page 15: General Layout

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 4.4 General Layout Manual 117 Issue 15 Page 15 of 24...
  • Page 16 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 4.5 Pump (If Required) Pump Head Connector Set Seal Kit Con-Rod Assembly MQ25 Pump Complete 230V 50/60H • Remove the pump from the SA unit. •...
  • Page 17 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 4.6 Replacing the Internal Hydrophobic Filter Warning! A hydrophobic filter must be fitted internally to prevent liquid passing through to the pump. Hydrophobic filters only work once and should be replaced immediately it becomes wetted.
  • Page 18 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 4.8 Flow Diagram SA 12 and SA 15 SA 14 and SA 16 Manual 117 Issue 15 Page 18 of 24...
  • Page 19 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 5. OPTIONS AND RECOMMENDED SPARES 5.1 Options User Instruction Manuals are offered in English. Other languages are available on request. Model Electrical Specification Collection Jars Power Cable Version 230Vac 50/60Hz...
  • Page 20 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual Filter capsule mounts with ‘o’ rings and fixings – 10pk MSP1017 Handle with fixings MSP1027 2amp 20mm fuses – 10pk MSP1225 Power cable – 2M MSP1377 5.2.3 Pump Components MQ25 Pump (Pump &...
  • Page 21: General Dimensions

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 6. TECHNICAL SPECIFICATION 6.1 General Dimensions                 SA 14 and SA 16 All Models Free air-flow (litres/minute): 30 lt/min nominal*...
  • Page 22: End Of Life

    SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 6.2 End of life IMPORTANT INFORMATION Correct disposal of the product in accordance with EC directive 2012/19/EU At the end of its life, the product must not be disposed of as urban waste. It must be taken to a special local authority differentiated waste collection centre or to a dealer providing this service.
  • Page 23 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 7. NOTES Manual 117 Issue 15 Page 23 of 24...
  • Page 24 SA 12, SA 14, SA 15 and SA 16 – UK Operation and Maintenance Manual 8. OTHER PRODUCTS IN THE RANGE Mains Powered Suction SA 17T - Thoracic Theatre suction unit SA 17W - Thoracic Ward suction unit SA 18 - Intensive care low vacuum suction unit SA 19 - Twin jar Intensive care low vacuum suction unit SA 35 - Major operating theatre high vacuum suction unit SA 36 - Twin jar intra-uterine aspirator unit...