One-Solar HSl-2KVA User Manual

One-Solar HSl-2KVA User Manual

Hybrid solar inverter

Advertisement

FOSHAN TOP ONE POWER TECHNOLOGY CO., LTD
Add: 4th Floor, Bldg. 6, No. 125 Zhangchayi Road, Chancheng
District, Foshan, Guangdong, PRC
Tel: +86 757 8258 0189
Fax: +86 757 8258 9791
Email: info@onesolarinverter.com
@ USER MANUAL
-
-
- - -
HYB RIO SOf.A
"' ""
= =
1-IYBRID
_
SOLAR INVERTER
- -
- -
--
RIN VER TeR
_
_

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HSl-2KVA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for One-Solar HSl-2KVA

  • Page 1 @ USER MANUAL - - - HYB RIO SOf.A "' "" RIN VER TeR _ � _ 1-IYBRID _ FOSHAN TOP ONE POWER TECHNOLOGY CO., LTD SOLAR INVERTER Add: 4th Floor, Bldg. 6, No. 125 Zhangchayi Road, Chancheng District, Foshan, Guangdong, PRC Tel: +86 757 8258 0189 Fax: +86 757 8258 9791 Email: info@onesolarinverter.com...
  • Page 2: Table Of Contents

    Catalogue 1. S a f et y P r e c a u t 1ons · · · · · · · · · · · · · · • • • • • • • • • • • • • • • • • • • • • • • • 01 2.
  • Page 3: S A F Et Y P R E C A U T 1Ons

    •••••• •••••• 1 . Safety Precautions 1 . Safety Precautions Battery Safety Operational Safety 1. The life of the battery is shortened as the ambient temperature increases. Regular battery 1. Please read "Safety Precautions" carefully before using this product to ensure correct and replacement ensures that the inverter is working properly and that sufficient backup time is safe use.
  • Page 4: Produc T App Ea Ranc

    HYEHID SOLAR IN\, 匕HJ>,H 酶 - 壬 画 一 壬 画 Identification Indicator light name Status AC Normal Inverter Battery inverter power supply HSl-2KVA HSl-3KVA HSl-4-6KVA @ FaulUWarning Warning/work abnormal • LCD Display Detailed display information 一一 2.1.Dimension • Navigation keys: selection, opening, obtaining information, modifying system...
  • Page 5: Botto M Ma

    ® {J)雹) 1. Installation of the must be performed by personnel with electrical safety knowledge. HSl-2KVA HSl-3KVA ► The wall on which the inverter is mounted must be sturdy and can withstand the weight of the inverter for a long time. (Please refer to the instruction manual for the weight of the inverter).
  • Page 6: Inverter Circuit Diagram

    The load output is output in addition to the terminal block Load mode. Some models provide socket output, and the output current cannot exceed 10A. 7.1. AC input and output load connection HSl-2KVA: SOLAR IN I AC INPUT I A C OUTPUT + 12V SYSTEM...
  • Page 7: Lcd Panel Operation

    •••••• •••••• 8. LCD Panel Operation 8. LCD Panel Operation ON/OFF Button : After pressing and holding for 3 seconds, you can turn off the 8.1. The main interface description is as shown power and turn it off. @ Press this button to display the data below: 的...
  • Page 8: Troubleshooting

    •••••• •••••• 9. Troubleshooting 10. Protection And Cleaning 10.1 Check the heat dissipation When the inverter is not working properly, we recommend the following solutions to eliminate common faults. The table below helps the technician understand the Check the environment around the inverter to eliminate the clogging of the vents. problem and take action.
  • Page 10: 2. T E C H Ni C Al Data Sh Eet

    •••••• 12. Technical Data Sheet Solar panel configuration requirements(PWM) Rated Rated Number of PV module load Max. input Solar panel current parallel volta volta e ( V ) power (re c om d val u e ) ( A ) roups 468W 624W...

This manual is also suitable for:

Hsl-3kvaHsl-4kvaHsl-5kvaHsl-6kva

Table of Contents