Page 3
••• ••• 1 . Safety Precautions 1 . Safety Precautions Battery Safety Operational Safety 1. The life of the battery is shortened as the ambient temperature increases. Regular battery 1. Please read "Safety Precautions" carefully before using this product to ensure correct and replacement ensures that the inverter is working properly and that sufficient backup time is safe use.
••• ••• 4.Unpacking Inspection 6.lnverter Circuit Diagram 1. Open the Package ,it should be include: 6.1 Protective Grounding 1) One unit Inverter If required for installation, the ground terminal can be used to connect to the second 2) Communication Wire(optional) level protective earthing terminal or as an equipotential bonding, as shown in the 3) External display (optional) following figure:...
••• ••• 6. Inverter Circuit Diagram 7. LCD Panel Operation The machine with relatively high power is connected to the mains input and load output 7 .1. The main interface description is as shown through the terminal block. The load output is output in addition to the terminal block mode.
Page 7
••• ••• 7. LCD Panel Operation 7. LCD Panel Operation 7.6. System mode setting 7.4. In the default main interface, long press the confirm button for five seconds (+J) to enter the setup menu, press the (T) button to scroll through the submenus. Set to In the default main interface, long press the confirm (千)...
Page 8
••• ••• 7. LCD Panel Operation 7. LCD Panel Operation 7 .8. Charging current setting 7.7. Battery type setting In the default main interface, long press the confirm button for five seconds to ( +J ) In the default main interface, the long press confirm key 5 seconds into the (+J) enter the setup menu, press the ( T ) button to select the charging current setting and...
••• ••• 7. LCD Panel Operation 9. Protection And Cleaning 7.9. Alarm setting 9.1 Check the heat dissipation 一 Unattended mode (],)] Alarm setting Check the environment around the inverter to eliminate the clogging of the vents. 岔需苍=砍- 因-已田蠲 Cleaning the device will improve the heat dissipation of the inverter. 令...
Page 10
_ _ ••• ••• 11.Technical Data Sheet 11. Technical Data Sheet ======= mlllmlllmlm!!mm!mm!mll!ml!m Rated power 1600W 2400W 3000W 3500W 4000W 5000W 6000W Charging mode Constant current, floating charge、 MPPT Capacity Peak power 4800W 7200W 9000W 10500W 12000W 15000W 18000W Overall Unit 12V/24V �96.5% /48V/96V...