eFlow102N Series
Power Supply/Chargers
Models Include:
eFlow102N/
eFlow102NX
- 10A @ 12VDC
eFlow102N8/
eFlow102NX8
- 10A @ 12VDC
- Eight (8) Fused Outputs
eFlow102N16/
eFlow102NX16
- 10A @ 12VDC
- Sixteen (16) Fused Outputs
Installation Guide
Rev. 102NRP020819
Installing Company: _______________ Service Rep. Name: __________________________________
Address: _____________________________________________ Phone #: __________________
eFlow102N8D/
eFlow102NX8D
- 10A @ 12VDC
- Eight (8) PTC Protected
Class 2 Power-Limited Outputs
eFlow102N16D/
eFlow102NX16D
- 10A @ 12VDC
- Sixteen (16) PTC Protected
Class 2 Power-Limited Outputs
Altronix Corp.
140 58th St. Brooklyn, NY
More than just power.
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the eFlow102N Series and is the answer not in the manual?

Questions and answers

Summary of Contents for EFLOW eFlow102N Series

  • Page 1 Series Power Supply/Chargers Models Include: eFlow102N/ eFlow102NX - 10A @ 12VDC eFlow102N8/ eFlow102N8D/ eFlow102NX8 eFlow102NX8D - 10A @ 12VDC - 10A @ 12VDC - Eight (8) Fused Outputs - Eight (8) PTC Protected Class 2 Power-Limited Outputs eFlow102N16/ eFlow102N16D/...
  • Page 2 Overview: Altronix eFlow102N power supply/chargers convert a 120VAC / 60Hz input to a 12VDC nominal output (see Power Supply Configuration Reference Chart and Specifications). eFlow102N Series Power Supply Configuration Reference Chart: Nominal DC Outputs [DC] [AUX] eFlow102N – – –...
  • Page 3: Specifications

    @ 1A (unswitched). • AC input and DC output LED indicators. Fuse/PTC Ratings: • Overvoltage protection. • Refer to eFlow102N Series Power Supply Battery Backup: Configuration Reference Chart, pg. 2. • Built-in charger for sealed lead acid or Additional Features: gel type batteries.
  • Page 4: Maintenance

    Loss of AC. Stand-by battery is supplying power. No DC output. Loss of AC. Discharged or no stand-by battery. No DC output. Power Distribution Module Green (AC) Power Distribution Module Status Normal operating condition. No Power Output. - 4 - eFlow102N Series Installation Guide...
  • Page 5: Terminal Identification

    Connect the circuit to the Batt Fail relay contacts to an appropriate input of a UL Listed Burglar Alarm or Access Control Panel. The following figure shows the circuitry needed for local annunciation. eFlow102N Series Installation Guide - 5 -...
  • Page 6 From From Power Power Supply Supply Board Board (Factory (Factory Installed) Installed) For continuous protection against risk of fire replace fuses with same type and rating 3.5A 250V - 6 - eFlow102N Series Installation Guide...
  • Page 7 Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. 7AH Rechargeable batteries are the largest batteries that can fit in this enclosure. A UL Listed external battery enclosure must be used if using 12AH, 40AH or 65AH batteries. eFlow102N Series Installation Guide - 7 -...
  • Page 8 Correct Wire Handling Handling External Jacketed Shield Wire Insulation * Outputs are non power-limited: eFlow102N, eFlow102N8, eFlow102N16. Outputs are Class 2 power-limited: eFlow102N8D, eFlow102N16D. Pull back Solid Copper external jacketed Conductors shield approx. 1/2”. - 8 - eFlow102N Series Installation Guide...
  • Page 9 Keep power-limited wiring separate from non power-limited. Use minimum 0.25" spacing. 12AH Rechargeable batteries are the largest batteries that can fit in this enclosure. A UL listed external battery enclosure must be used if using 40AH or 65AH batteries. eFlow102N Series Installation Guide - 9 -...
  • Page 10 Correct Wire Handling Handling External Jacketed Shield Wire Insulation * Outputs are non power-limited: eFlow102NX, eFlow102NX8, eFlow102NX16. Outputs are Class 2 power-limited: Pull back eFlow102NX8D, eFlow102NX16D. Solid Copper external jacketed Conductors shield approx. 1/2”. - 10 - eFlow102N Series Installation Guide...
  • Page 11 (30.5mm) 0.75” 0.75” 12.5” (317.5mm) 1.20” 1.20” (19.1mm) (19.1mm) (30.5mm) (30.5mm) 11.0” (279.4mm) 0.9375” (23.8mm) 1.40” 1.40” (35.6mm) (35.6mm) 0.9375” (23.8mm) 3.25” (82.6mm) 3.25” (82.6mm) 1.0” (25.4mm) 1.0” 1.0” 10.5” (266.7mm) (25.4mm) (25.4mm) eFlow102N Series Installation Guide - 11 -...
  • Page 12 (31.8mm) 1.1” (27.9mm) 1.1” (27.9mm) 1.375” 1.5” 1.5” (34.9mm) (38.1mm) (38.1mm) 1.125” (28.6mm) 2.0” (50.8mm) 2.0” (50.8mm) 1.25” (31.8mm) 1.25” (31.8mm) 1.1” (27.9mm) 1.75” (44.5mm) 1.5” 1.5” 4.615” (117.2mm) 4.615” (117.2mm) (38.1mm) (38.1mm) - 12 - eFlow102N Series Installation Guide...
  • Page 13: Appendix A - Ul Listed Compatible Devices

    Projected Beam 28.4 Beam 1224(S) Projected Beam 38.5 * Contact manufacturer for current draws. –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– A.2 Relays Table A-2 below lists relays compatible with eFlow102N output. Manufacturer Model Current (mA) System Sensor EOLR-1 eFlow102N Series Installation Guide - 13 -...
  • Page 14 - UL Listed in the U.S. and Canada. - Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN. - Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, input trigger state change, output state change and unit temperature.
  • Page 15 Altronix is not responsible for any typographical errors. 140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056 website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty | Made in U.S.A. IIeFlow102N Series G23U MEMBER eFlow102N Series Installation Guide - 15 -...
  • Page 16 3.5A – 760mV eFlow102NX, eFlow102NX8, Flow102NX8D, eFlow102NX16, eFlow102NX16D Overview: The eFlow102N series power supply/chargers convert a 120VAC, 60Hz input to a 12VDC output. Stand-by Specifications: Burg. Applications Fire Applications 4 hr. Stand-by/ 24 hr. Stand-by/ Access Control Battery 15 min.