Download Print this page

MORDOMUS Meteo-1706 Instructions

Weather sensor

Advertisement

Quick Links

1. GENERAL FEATURES :
Reading points: 4, temperature, light, wind intensity and rain
detection;
Command: Via MD BUS;
Applications: Weather information current;
Installation: Outside the building.
2. GENERAL SPECIFICATIONS :
Voltage: 12VDC;
Consumption: 150mA @ 12VDC;
Storage Temperature: -10ºC to 60ºC;
Temperature Operating: -60ºC to 60ºC;
Readings:
Temperature: -60ºC to 60ºC;
Brightness: 10 levels;
Wind: 10 levels;
Rain: true/false;
Physical Specifications:
Box Plastic, self-extinguishing UL-94 V0;
Level of Protection: IP54, for outdoor use.
Directives:
-Electromagnetic Compatibility Directive / EMC
Directive 2004/108/EC
3. COMPATIBILITY :
PCCWd Compatibility: Firmware 3.4 or higher version V3.2
or V3.31 with BUS Adapter;
Mordomus Software Compatibility: Mordomus Software
v2015.2 or higher;
Manual: Meteo-1706-EN
Meteo – Weather Sensor
4. SECURITY :
Before
instructions.
5. INSTALLATION:
Note that if the METEO is installed to direct sunlight will
measure temperatures according to the exposure, and
different temperatures may be measured in the shade.
If the chosen location for METEO has a difficult access and/or
remote to the Mordomus console, it is advisable to carry out
the address through a previous temporary connection with the
frame and the console.
After this previous assemble the METEO in its place.
6. CONNECTIONS:
Thickness of conductors:
In case of installation with BUS ADAPTER, METEO
should be at the end of RX Bus chain.
Connect the Bus:
To connect the BUS should use a twisted pair cable CAT6.
For example: Green for A and Green/White to B. The shield
should be connected to GND.
Connect the 12VDC power:
It is recommend the use of Mean-Well power supplies, DR60-
12 and DR30-12.
www.mordomus.com
making
any
connections,
1.
Must handle carefully the parts of the module and
ensure ITS correct assembly;
2.
It is important to establish the place of installation so
METEO IS exposed to the elements so then can be
measure.
3.
METEO
should be inclined 45 ° relative to the
horizon, so that the rain water runs down, as the Fig.
4;
4.
Do not paint or polish METEO sensitive surface;
5.
The accumulation of dirt on the rain sensor limits its
sensitivity, which must be cleaned twice a year with
a damp cloth or when it shows signs of dirt or
incorrect readings.
Circuit Bus:
CAT6 Cable F/UTP shielded, twisted;
Power Circuit:
CAT6 Cable F/UTP shielded, twisted;
Hardware: V4.0
Firmware: V4.4
please
read
these
Page 1/2

Advertisement

loading
Need help?

Need help?

Do you have a question about the Meteo-1706 and is the answer not in the manual?

Questions and answers

Summary of Contents for MORDOMUS Meteo-1706

  • Page 1 If the chosen location for METEO has a difficult access and/or Box Plastic, self-extinguishing UL-94 V0; remote to the Mordomus console, it is advisable to carry out Level of Protection: IP54, for outdoor use. the address through a previous temporary connection with the frame and the console.
  • Page 2 7. ADDRESSING AND CONFIGURATION : After connected and powered, perform the following steps: Fig 2: Open "Register modules" in the Mordomus software; Press address (Addressing) inside the module. The Green LED will blink slowly and the red LED will pulse once.