Remington Silent Drive RPH75R User's Manual & Operating Instructions

Remington Silent Drive RPH75R User's Manual & Operating Instructions

Kerosene / diesel heater

Advertisement

KEROSENE / DIESEL HEATER
USER'S MANUAL & OPERATING INSTRUCTIONS
RPH75R
DANGER
READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING,
OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided with this heater. Failure
to comply can result in fire or explosion that can cause property loss, bodily injury, or loss of life. Only persons who
can follow and understand these instructions should operate or service this heater. If you need heater info; such as an
operating manual, labels, etc. Please visit our website www.remingtonpower.co.nz
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY FOR: The temporary heating of adequately ventilated
buildings or structures under construction , alteration or repair . This is an unvented portable heater that uses air
(Oxygen) from within the area in which it is used. Failure to provide adequate combustion and ventilation air will result in
asphyxiation, carbon monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 7.
www.remingtonpower.co.nz

Advertisement

Table of Contents
loading

Summary of Contents for Remington Silent Drive RPH75R

  • Page 1 KEROSENE / DIESEL HEATER USER’S MANUAL & OPERATING INSTRUCTIONS RPH75R DANGER READ AND UNDERSTAND ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be sure to comply with the instructions and warnings provided with this heater. Failure to comply can result in fire or explosion that can cause property loss, bodily injury, or loss of life.
  • Page 2: Table Of Contents

    CONTENTS Introduction........3 Environmental Protection....3 Safety Information......3 Specifications........5 Features.........5 Assembling the Generator....6 Operation........7 Maintenance.........9 Storage........10 Troubleshooting......11 Parts List........12 Wiring Diagram......14 Warranty........15 www.remingtonpower.co.nz...
  • Page 3: Introduction

    Refer to “Ventilation” on page 7. Bulk fuel storage should be a minimum of 8 metres from heater. Your new Remington Heater will more than satisfy your expectations. It has been manu- WARNING: Do not operate this...
  • Page 4 ALWAYS unplug the heater when not in use. WARNING: Carbon monoxide poisoning may lead to death! ALWAYS install the heater so that it is not di- rectly exposed to water spray, rain, dripping Carbon monoxide is toxic. Humans can water, or wind. tolerate only small amounts of carbon mon- oxide and so precautions should be taken to provide proper ventilation.
  • Page 5: Specifications

    RPH75R KEROSENE / DIESEL HEATER SPECIFICATIONS Model #: RPH75R Rating: 70,000 Btu/Hr Fuel Consumption: 1.8L/Hr Fuel Tank Capacity: Max Operating Hours: Volts: 230V / 50Hz Amps: <5A Heating Area: 162m Specifications subject to change without notice. FEATURES Figure 1. www.remingtonpower.co.nz...
  • Page 6: Assembling The Generator

    Carry Handle Assembly 1. Align holes in the upper housing with the 2 holes in the handle as shown in Figure 2. 2. Insert screws and tighten firmly. Figure 2. ASSEMBLY INSTRUCTIONS Remove the heater and all packaging materi- als from the shipping carton. Save the box and packaging materials for future storage.
  • Page 7: Operation

    RPH75R KEROSENE / DIESEL HEATER OPERATION NEVER store Kerosene in direct sunlight or near a source of heat. Fueling The Heater NEVER use Kerosene that has been stored from one season to the next. Kerosene dete- Kerosene or Diesel riorates over time. OLD Kerosene WILL NOT This heater is multi-fuel rated.
  • Page 8 Starting The Heater (Ignition) 1. Complete previous steps 1 - 3. 1. Fill the tank with Kerosene or other ap- 2. Push the power switch to the “ON” posi tion. The power indicator lamp will light proved fuel until needle on fuel gauge points to “F”.
  • Page 9: Maintenance

    RPH75R KEROSENE / DIESEL HEATER Nozzles MAINTENANCE Nozzles should be cleaned or replaced WARNING: Never service heater at least once per heating season. Con- while it is plugged in or hot. taminated fuel could make this necessary immediately. To clean dirt from nozzle, blow Do not tamper with the unit.
  • Page 10: Storage

    Photocell Storage The photocell should be cleaned at least Long Term Storage once per heating season or more depending on conditions. Use a cotton swab and water 1. Unscrew the fuel cap. or alcohol to clean the lens of the photocell. Be certain to reinstall the photocell in proper 2.
  • Page 11: Troubleshooting

    RPH75R KEROSENE / DIESEL HEATER TROUBLESHOOTING PROBLEM (SYMPTOMS) POSSIBLE CAUSE SOLUTION www.remingtonpower.co.nz...
  • Page 12: Parts List

    PARTS LIST Some parts listed may be unavailable. Figure 10. www.remingtonpower.co.nz...
  • Page 13 RPH75R KEROSENE / DIESEL HEATER Item # Description Temperature Limit Switch Fuel Tank Assembly Chamber Assembly Oil Filter Assembly Chamber Insulator Fuel Pipe Ceramic Fibre Fuel Packing Heat Plate Fuel Hose Shell Ring Fuel Gauge Assembly Safety Guard Fuel Cap Assembly Burner Body Cooling Fan Housing Spark Plug...
  • Page 14: Wiring Diagram

    WIRING DIAGRAM Figure 11. www.remingtonpower.co.nz...
  • Page 15: Warranty

    1. DURATION: The manufacturer warrants that it will repair or replace, at no charge for parts or labour, the 7. RESPONSIBILITIES OF PURCHASER UNDER THIS Remington Heater, if proven defective in material WARRANTY: or workmanship, during the following time period(s) after date of original retail purchase: A.
  • Page 16 Congratulations on your new Remington product. We are proud to have you as our customer and will strive to provide you with the best service and reliability in the industry. This product is backed by our extensive warranty and service network. Please contact your local agent or submit a service case online for fast response at www.remingtonpower.co.nz and find the...

Table of Contents