REM-45-KFA-O / REM-80T-KFA-O / REM-140T-KFA-O / REM-190T-KFA-O / REM-215T-KFA-O
CONSUMER: READ AND SAVE THESE INSTRUCTIONS
Locating Your Serial Number:
Your serial number can be found on a white label on the right side cover of your heater. For Exam-
ple: 150812779. Have your Serial Number ready before calling customer service at 866-676-1989.
DANGER
sure to comply with the instructions and warnings provided with this heater. Failure to
comply can result in fire or explosion that can cause property loss, bodily injury, or loss
of life. Only persons who can follow and understand these instructions should operate or
service this heater. If you need heater info; such as an operating manual, labels, etcetera,
contact Pinnacle Climate Technologies at 866-676-1989.
DANGER
FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS OR
STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an unvented
portable heater that uses air (Oxygen) from within the area in which it is used. Failure
to provide adequate combustion and ventilation air will result in asphyxiation, carbon
monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 6.
FACTORY ID: 001
MODEL NUMBERS:
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER. Be
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN
ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989
Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com
KEROSENE FORCED AIR HEATER
User's Manual &
Operating Instructions
© 2018 Pinnacle Climate Technologies, Inc.
RGKI-403

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Remington REM-45-KFA-O

  • Page 1 User’s Manual & Operating Instructions MODEL NUMBERS: REM-45-KFA-O / REM-80T-KFA-O / REM-140T-KFA-O / REM-190T-KFA-O / REM-215T-KFA-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS Locating Your Serial Number: Your serial number can be found on a white label on the right side cover of your heater. For Exam- ple: 150812779.
  • Page 2: Table Of Contents

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE TABLE OF CONTENTS Safety Information..........2-3 Maintenance.............8-9 What’s in the Box..........4 Wiring Diagrams..........10 Specifications............5 Troubleshooting Guide........11 Features.............5 Exploded View..........12 Assembly Instructions.........5 Parts List............13 Opeation............6-7 Limited Warranty..........14 SAFETY INFORMATION FIRE, BURN, INHALATION AND EXPLOSION HAZARD.
  • Page 3: Safety Information

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE SAFETY INFORMATION (CONT.) WARNING WARNING RISK OF INDOOR RISK OF ELECTRIC AIR POLLUTION! SHOCK! The products described in this manual are ALWAYS use only the electrical power (voltage and frequency) specified on the model plate of the heater.
  • Page 4: What's In The Box

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE WHAT’S IN THE BOX (45-KFA / 80T-KFA) Cord Wraps (Optional) Carry Handle (1) Shown With Optional Cord Wraps Heater (1) 15 mm Screws (2) 10 mm Screws (2) WHAT’S IN THE BOX (140T-KFA / 175T-KFA / 215T-KFA) Tip: Be sure to remove the axle from the side of the Styrofoam packaging.
  • Page 5: Specifications

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE SPECIFICATIONS Model # 45-KFA 80T-KFA 140T-KFA 190T-KFA 215T-KFA Rating: Btu/Hr 45,000 80,000 140,000 190,000 215,000 Fuel Consumption: Gal/Hr 0.35 0.63/2.38 1.1/4.16 1.42 1.63 Fuel Tank Capacity: Gallons Pump Pressure: psi Volts: AC/Hz 120VAC / 60Hz 120VAC / 60Hz 120VAC / 60Hz 120VAC / 60Hz 120VAC / 60Hz...
  • Page 6: Opeation

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE OPERATION Fueling The Heater: NOTE: Kerosene should only be stored in a blue container that is clearly marked “Kerosene.” Kerosene (K-1) Never store kerosene in a red container. Red is For optimal performance of this heater, it is associated with gasoline.
  • Page 7 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE OPERATION (CONT.) Stopping / Restarting Heater: Starting the Heater: (Ignition) - To stop the heater, move the power switch to the 1. Fill the tank with kerosene or other approved “Off”...
  • Page 8: Maintenance

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE MAINTENANCE Service: ROTOR: The rotor with carbon vanes should be evaluated DO NOT TAMPER WITH THE UNIT. HAVE every heating season. The rotor is behind the air A COMPETENT SERVICEMAN MAKE ANY filters.
  • Page 9 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE MAINTENANCE (CONT.) Service (Continued): PUMP PRESSURE: While heater is operating, turn adjusting screw SPARK PLUG: clockwise to increase, counter-clockwise to Clean and re-gap every 600 hours of operation, or decrease pressure.
  • Page 10: Wiring Diagrams

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE WIRING DIAGRAMS 45-KFA 80T - 215T-KFA 80T-KFA 140T-KFA / 175T-KFA / 190T-KFA (80T-KFA) (140T-KFA) (175T-KFA / 190T-KFA / 215T-KFA) Models 140T/175T/190T/215T-KFA have a digital display. © 2018 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 11: Troubleshooting Guide

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE TROUBLESHOOTING GUIDE Problem Possible Cause Solution Heater Ignites, but main PCB shuts 1. Incorrect pump pressure. 1. Adjust pump pressure. off after a short period of time. 2.
  • Page 12: Exploded View

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE EXPLODED VIEW 33** 34** 40** 35** 37** 36** 43** * 45-KFA - 80T-KFA Only 38** ** 140T-KFA - 215T-KFA Only 42** © 2018 Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Page 13: Parts List

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE PARTS LIST Description 45-KFA 80T-KFA 140T-KFA 190T-KFA 215T-KFA Drain Bolt – – 70-002-0115 70-002-0115 70-002-0115 Fuel Gauge 70-007-0110 70-007-0110 70-007-0215 70-007-0215 70-007-0215 Fuel Filter 70-003-0100 70-003-0100 70-003-0200 70-003-0200 70-003-0200 Fuel Cap - Large Plastic...
  • Page 14: Limited Warranty

    NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater to If Pinnacle Climate Technologies, Inc. finds the item to be the original retail purchaser only, to be free from defects in in normal operating condition, or not defective the item material and workmanship for a period of one (1) year from will be returned freight collect.
  • Page 15 Manual del usuario e instrucciones de operación MODELOS N.° REM-45-KFA-O / REM-80T-KFA-O / REM-140T-KFA-O / REM-190T-KFA-O / REM-215T-KFA-O CONSUMIDOR: LEA Y CONSERVE ESTAS INSTRUCCIONES Cómo localizar su número de serie: El número de serie lo puede encontrar en una etiqueta blanca en el lado derecho de la cubierta de su calentador.
  • Page 16 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN ÍNDICE Información de seguridad ........2-3 Mantenimiento ............8-9 Qué hay en la caja ............. 4 Diagramas eléctricos ..........10 Especificaciones ............5 Guía para la solución de problemas .......
  • Page 17: Información De Seguridad

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN INFORMACIÓN DE SEGURIDAD (CONTINÚA) ¡RIESGO DE ¡RIESGO DE DESCARGA CONTAMINACIÓN ELÉCTRICA! DEL AIRE INTERIOR! SIEMPRE utilice la energía eléctrica (voltaje y frecuencia) Los productos descritos en este manual son que se indica en la placa de modelo del calentador.
  • Page 18: Qué Hay En La Caja

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN QUÉ HAY EN LA CAJA (45-KFA / 80T-KFA) Enrolladores de cable Asa (1) (Opcional) Ilustrado con enrolladores de cable opcionales Calentador (1) Tornillos de 10 mm (2) Tornillos de 15 mm (2) QUÉ...
  • Page 19: Especificaciones

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN ESPECIFICACIONES N.° de modelo 45-KFA 80T-KFA 140T-KFA 190T-KFA 215T-KFA Capacidad nominal: Btu/H 45,000 80,000 140,000 190,000 215,000 Consumo de combustible: Gal/H 0.35 0.63/2.38 1.1/4.16 1.42 1.63...
  • Page 20: Funcionamiento

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN FUNCIONAMIENTO Llenar de combustible el calentador: - NUNCA utilice queroseno que haya estado almacenado de una temporada a la siguiente. El queroseno se Queroseno (K-1) deteriora con el tiempo.
  • Page 21 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN FUNCIONAMIENTO (CONTINÚA) - Entre 0 °F (-18º C) y 99 °F (37 ºC) la pantalla mostrará Encendido del calentador: (Ignición) la temperatura real. 1.
  • Page 22: Mantenimiento

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN MANTENIMIENTO Servicio: el extremo de plástico colocado debajo del soporte NO ALTERE LA UNIDAD. PIDA A UN TÉCNICO del motor/motor y alejado del aspa del ventilador. COMPETENTE QUE HAGA LAS REPARACIONES ROTOR: O AJUSTES NECESARIOS.
  • Page 23 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN MANTENIMIENTO (CONT.) Servicio (Continuación): PRESIÓN DE LA BOMBA: Mientras el calentador está funcionando, gire la BUJÍA: válvula de seguridad hacia la derecha para aumentar Límpiela y reajuste la separación entre los la presión o hacia la izquierda para disminuirla.
  • Page 24: Diagramas Eléctricos

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN DIAGRAMAS ELÉCTRICOS 45-KFA PCI DE CONTROL NEGRO ROJO BUJÍA ENCEN- DEDOR ROJO NEGRO LUZ (LED) NARANJA NEGRO VENTILADOR 1 MOTOR DE LA BLANCO ROSA VENTILADOR 2 BOMBA...
  • Page 25: Guía Para La Solución De Problemas

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GUÍA PARA LA SOLUCIÓN DE PROBLEMAS Problema Posible causa Solución El calentador se enciende, pero la 1. Presión de la bomba incorrecta. 1. Ajuste la presión de la bomba. placa de circuitos impresos principal 2.
  • Page 26: Vista Detallada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN VISTA DETALLADA 33** 34** 40** 35** 37** 36** 43** * Sólo 45-KFA - 80T-KFA 38** ** Sólo 140T-KFA - 215T-KFA 42** © 2018 Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Page 27: Lista De Piezas

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN LISTA DE PIEZAS Descripción 45-KFA 80T-KFA 140T-KFA 190T-KFA 215T-KFA Perno de drenaje – – 70-002-0115 70-002-0115 70-002-0115 Indicador de combustible 70-007-0110 70-007-0110 70-007-0215 70-007-0215 70-007-0215 Filtro de combustible...
  • Page 28: Garantía Limitada

    NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GARANTÍA LIMITADA Pinnacle Climate Technologies, Inc. garantiza este descubre que el artículo está en condiciones normales de calentador únicamente al comprador minorista original, funcionamiento o que no está...