NOTE: This guide is only meant to assist in identifying the unit and its included accessories, if any, and to
assist you with initial setup of the unit. It does not describe all of the unit's features and capabilities in detail.
Please refer to the full user manual, available for download from our web site at www.geistglobal.com, for
Ÿ Watchdog 15 or 15P environmental monitor (NOTE: the "P" means the unit has the Power-over-Ethernet
option installed. The two models are otherwise identical in function and capabilities.)
Ÿ +6Vdc power supply (unless the "no power supply" option was chosen when the unit was ordered)
A
B
Ÿ Watchdog 100 or 100P environmental monitor (NOTE: the "P" means the unit has the Power-over-
Ethernet option installed. The two models are otherwise identical in function and capabilities.)
Ÿ Two (2) detachable mounting brackets to mount the unit in a 19" 1U rackmount space (the unit is shipped
with these brackets already attached; they can be removed if desired.)
Ÿ +6Vdc power supply (unless the "no power supply" option was chosen when the unit was ordered)
Watchdog 100
C
Digital Sensor jacks: Up to four Digital Bus-type external sensors can be connected to the unit. (may
A
require an external port-splitter, sold separately)
B
Temperature/Humidity sensor: Make sure that this is not blocked or covered up when the unit is mounted.
C
DC power jack: +6VDC power supply connects here.
Ethernet jack: Right LED indicates network state: "link" (solidly lit) and "activity" (blinking). Left LED
D
indicates the link speed. (100Mbit connection when lit; 10Mbit-only if unlit.)
E
RESET button: To reset the IP address to the factory default of
username/password settings, hold in this button for approximately 20 seconds, until both of the red
Account
Active and Idle LEDs light up solidly (no blinking pattern). On a Watchdog 15 or 15P, use a pushpin or bent
paperclip to press the button behind the pinhole opening under the Ethernet jack.
To completely erase all settings and reset the unit to factory defaults, disconnect power from the unit, push in the
reset button, reapply power, keep the reset button pushed in for at least 5 seconds, then release.
Active / Idle LEDs: Indicates that the unit is operating, and communicating with the sensor-bus controller
F
and external sensors (if any).
Analog Inputs: Used to monitor dry-contact switches or relay contacts, or for analog sensors with 0 ~
G
+5Vdc output voltages. (WatchDog 100 or 100P only)
Relay Output: Dry-contact relay for controlling external low-voltage devices. The LED under the terminal
H
block shows the relay's state: de-energized (red) or energized (green). (WatchDog 100 or 100P only)
Watchdog 15/100 quick-setup pack-in sheet, rev150213A
complete information about how to use all of the unit's capabilities.
Watchdog 15 /15P kit includes:
Watchdog 15
Watchdog 100 / 100P kit includes:
D F E
(sample illustrations only; actual appearance of unit may vary)
C
1
C
2
C
3
C
4
N
N
C
C
O
G
H
192.168.123.123
1
C
D
E
B
and clear any
http://www.interworldna.com 
F
A
User

Advertisement

loading

Summary of Contents for Geist Watchdog 15

  • Page 1 20 seconds, until both of the red Account Active and Idle LEDs light up solidly (no blinking pattern). On a Watchdog 15 or 15P, use a pushpin or bent paperclip to press the button behind the pinhole opening under the Ethernet jack.
  • Page 2 IP address, simply repeat the steps above, and change the PC’s NIC card settings back to the ones you wrote down prior to changing them, to restore the PC’s normal network and internet settings. Watchdog 15/100 quick-setup pack-in sheet, rev150213A http://www.interworldna.com ...
  • Page 3 IP address, and have been able to bring up its Overview page in your web browser using the “Quick-Start Network Setup” instructions on the preceding page. Since the Watchdog 15 and 100 models share the same user interface, only the Watchdog 15’s web pages are shown here.) Before the Watchdog unit can log data, its real-time clock must be set to the correct time.
  • Page 4 “Tripped” message should disappear from the web page, the current-temperature reading will turn black again, and you should receive an e-mail with a subject line of “Watchdog 15: Cleared”. If you have successfully managed to perform the above steps, then... congratulations! The unit is now correctly set up for your network and SMTP service, and is ready to use.

This manual is also suitable for:

Watchdog 15pWatchdog 100Watchdog 100p