SAFETY AND GUIDANCE NOTES
All wiring to be in accordance with the current I.E.E. Regulations, or
the appropriate standards of your country and MUST be installed
by a suitably qualified person.
The Fan should be provided with a local isolator switch capable of
disconnecting all poles, having a contact separation of at least
3mm.
Ensure that the mains supply (Voltage, Frequency, and Phase)
complies with the rating label.
The Fan should only be used in conjunction with the appropriate
Airtech products.
The fan should only be used in conjunction with fixed wiring.
When the Fan is used to remove air from a room containing a fuel-
burning appliance, ensure that the air replacement is adequate for
both the fan and the fuel-burning appliance.
The Fan should not be used where it is liable to be subject to direct
water spray for prolonged periods of time.
Where ducted Fans are used to handle moisture-laden air, a
condensation trap should be fitted. Horizontal ducts should be
arranged to slope slightly downwards away from the Fan.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the appliance by a
person responsible for their safety.
Young children should be supervised to ensure that they do not
play with the appliance.
This product should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority for recycling advice.
IPX4

Advertisement

loading
Need help?

Need help?

Do you have a question about the ACR60 and is the answer not in the manual?

Questions and answers

Summary of Contents for AirTech ACR60

  • Page 1 IPX4 ACR60 ACR60LV Installation and Wiring Instructions SAFETY AND GUIDANCE NOTES All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country and MUST be installed by a suitably qualified person. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a contact separation of at least 3mm.
  • Page 3: Installation

    DESCRIPTION The fan is a continuously running extract fan for kitchens, utility rooms, bathrooms and toilets. The incorporated LED display allows the installer to configure the fan to suit its installation. The display is also used to display the day logger and power run meter. The fan can be wall, window or panel/ceiling mounted.
  • Page 4 WIRING WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. IMPORTANT The cross-sectional area of supply cord used should be ranged from 1 -1.5mm The extraction fan or transformer (SELV model) is suitable for connection to 220-240V 50Hz supply.
  • Page 5 Boost time b01 to b30 – 1 to 30 minutes 15 minutes Humidity level trigger h50 to h70 - 50% to 70% relative humidity 60% RH Comfort mode c-n = normal boost c-y = comfort mode operation * This setting rotates the display only; the buttons retain their original function. For example; the mode button is on the right when in normal rotation and on the left when the screen is rotated and looking at the fan so the display is correctly orientated.
  • Page 6 LS activated boost pulling the pullcord will first enter boost a further pull will return the fan to trickle. Data Logger (ACR60 model) With the fan powered up; upon removing the cover the display will automatically activate. It will display the commissioning options.
  • Page 7: Servicing And Maintenance

    Data Examples Text scrolling from right to left In this example the display is showing a total run time of 1 year and 237 days. Text scrolling from right to left In this example the display is showing 34Wh of energy consumption in the previous 24h. Returning to commissioning mode A further 5 second press of the Mode button will return the fan to the commissioning menu.
  • Page 8 3. Water is dripping out of the fan when installed in a ceiling: a. Cause: i. This is caused by condensation forming on the inside of the ducting and dripping out of the fan inlet. b. Solution: i. This is normal and the fan is designed to handle condensation build up. However a condensation trap connected immediately after the fan will help to prevent water dripping into the room.
  • Page 9 Fig.3. Continuous trickle with boost facility. (The fan is internally fused) Fig.4 Continuous trickle with pullcord boost ACR60LV model 1 Phase Supply (220-240V 50Hz). FUSE 24v D.C 12V D.C SELV Supply Switched Fused Spur (3A) Controller Fig.5 Continuous boost 1 with no trickle facility ACR60LV model 24v D.C 12V D.C 1 Phase Supply...
  • Page 10 Fig.6 Continuous trickle with boost facility via LS or internal pullcord, ACR60LV model 24v D.C 12V D.C SELV Supply Controller...
  • Page 11 Fig.7. Removing the grille for wiring and setup 2. Pull the grille clear of the screw and lift away Note: ACR60 models; do NOT attempt to pull off the flat front cover. 1. Loosen the screw at the bottom of the grille...
  • Page 12 AIRTECH ENVIRONMENTAL SYSTEMS STATHE ROAD, BURROWBRIDGE, SOMERSET, TA7 0RY Tel : 0800 378 017 477775 A 1117...

This manual is also suitable for:

Acr60lv