Aquabrass votre produit Aquabrass product By purchasing an Aquabrass/Alt product, you are taking En achetant un produit Aquabrass/Alt, vous prenez part in the global movement for better living. We take part au mouvement global pour le mieux-vivre. Nous pride in manufacturing drinking water faucets that are sommes fiers de fabriquer des robinets d’eau potable...
Page 3
VALVE COMPONENTS Project Divison Projet COMPOSANTES DE LA VALVE SPECS AT LARGE / SCHÉMA DES PIÈCES ALT760705: check valve/ valve d'arrêt ABSP61200: 1/2' NPT Diverter plug / Bouchon du déviateur 1/2' NPT ABSP61201: Adaptor / Extension for ThermOn ABHS62088PC e / Adaptateur / Extension pour ThermOne ABSP61202: Rubber gaskets / Joints en caoutchouc ABSP61203: Legs extension / Extensions ABSP61204: Spacer / Espaceur...
Page 4
BEFORE YOU START Project Divison Projet AVANT DE COMMENCER CAUTION: FOR BEST RESULTS, WE STRONGLY REC- MISE EN GARDE: POUR OBTENIR UN RÉSULTAT OMMEND THE INSTALLATION OF THIS VALVE BE DONE OPTIMAL, NOUS RECOMMANDONS FORTEMENT QUE BY A LICENSED PLUMBER. L’INSTALLATION DE CETTE VALVE SOIT FAITE PAR UN PLOMBIER ACCRÉDITÉ.
Page 5
Project Divison Projet INSTALLATION A How to Use the Plastic Protector Cap The valve is covered by a plastic protector cap. It can be used as a template for setting the depth of the valve in the wall. The finished wall can fall anywhere along the side of this plastic guard (Fig.1).
Project Divison Projet INSTALLATION A Installing the valve Min [54.00] 2 1/8” Max [78.00] 3 1/16” Once the mixer location is determined, position the valve in between 2x4 studs inside the wall on a plywood backing for better support. Make sure the valve is level and at the right depth before securing it firmly in place.
Page 7
Project Divison Projet INSTALLATION B (Thin wall) How to Use the Plastic Protector Cap in a thin wall (3/8" or less) For this installation, you will need to also have the selected trim components at hand. The "Thin Wall" method is used when the tub/shower wall is less than 3/8"...
Project Divison Projet INSTALLATION B (Thin wall) Installing the cartridge Unscrew the cartridge holder (1) and remove the protective plug. Fig. 6. Make sure the "top" brass spacer remains in place (3). Insert the cartridge (2) into the valve body as shown. Fig.6. Make sure its guiding lugs line-up with the corresponding open- ings in the rough.
Project Divison Projet INSTALLATION A / B Connecting the Water TO THE SHOWER HEAD VERS LA TÊTE DE DOUCHE Connect the hot and cold water inlets and the mixed water outlets. Fig.8. The hot water must always be con- nected on the left side and the cold water on the right, as indicated on the valve body.
Project Divison Projet MAINTENANCE To Service The Cartridge Shut off the main water supply, then remove all the components from (1) to (6). Fig.9. Afterwards, shut off the 2 check valves (9) by turning them clockwise with a screwdriver. Unscrew the cartridge holder (7) and remove the cartridge (8).
Page 11
CARE Project Divison Projet SOIN To clean your Aquabrass faucet or accessory, wash with a wet nonabrasive soapy cloth. Then wipe dry with a soft towel or cloth. We recommend this be done on a regular basis. DO NOT USE ANY ABRASIVE, CHEMICAL OR CORROSIVE, POWDER OR ANY OTHER STRONG CLEANERS INCLUDING DETERGENTS, WINDOW CLEANERS AND DISINFECTANTS ON YOUR Aquabrass PRODUCT as they will destroy the finish and therefore VOID THE WARRANTY.
Project Divison Projet Limited lifetime warranty All Aquabrass products carry a full warranty against defects in materials and workmanship. The warranty will be applied only if the product is purchased from an authorized Aquabrass dealer. The Aquabrass warranty is limited strictly to the original consumer purchaser of the product. Proof of purchase must be made available to aquabrass for all limited warranty claims.
Page 13
Project Divison Projet Project Divison Projet last revision: 14/05/2018...