Put the unit into its place using the adjustable feet. If the unit is added to an existing kitchen line, bring it
to the same height by adjusting the feet and combine it with the suitable connection system.
If you are installing a built-in model carefully check and precisely follow the relative built-in drawing
supplied with the unit itself.
The air circulation openings of the built-in module must be transferred to an eventually existing partition
sheet and by no means be clogged in order to assure the primary air intake. If the kitchen module does
not have air circulation openings, then remove the existing partition sheet and use the one of the built-in
module. In case of doubts, please contact your retailer/wholesaler.
Please determine the exact gas type the unit is set with through the technical data plate placed near the
gas connection and on the packing. The unit must be installed only through authorised, trained and
licensed personnel following the local rules and regulations. Make sure to also follow the rules and
regulations of the local gas supply company. The unit must be operated only by trained personnel.
The gas unit must be installed only in adequately ventilated/aired areas as the contrary could lead to
serious consequences due to combustion residues and/or low oxygen environment air. The installation
room must not be modified after installation of the gas unit. Never ignite the gas unit, if there is a strong
gas smell in the air; open wide windows and doors to change the air inside the room and check the gas
connections for leaks. If you can't determine the leak position, close the main gas tap and contact your
retailer/wholesaler for a profound analysis of the gas connection system. The unit must be installed only
through authorised, trained and licensed personnel following the local rules and regulations. Make sure to
also follow the rules and regulations of the local gas supply company. Prior to installation, the gas unit
must be checked for dimensions, power and OEM set gas type. If locally there is another gas type
available, only authorised, trained and licensed personnel can substitute the nozzle installed by the OEM.
The exact gas type the unit is set with is indicated on the technical data plate placed near the gas
connection and on the packing. The supply includes also the nozzles for different gas types, enabling the
substitution. Connection to the main gas tap must be carried out exclusively through the OEM gas train.
The gas pressure must be measured and checked. The gas train is equipped with a measuring pipe ( see
image). Loose the screw of the pipe (without removing it) and apply the gas pressure measuring
equipment over it and measure the gas pressure. Tighten the screw after measuring and check if the gas
train is sound by applying soapy water on the joints.
follows
Version 1.3
Page 4 of 20
13.01.2016