Viavi T-BERD 5800 Quick Card

Viavi T-BERD 5800 Quick Card

Network tester ds1 ppp ping testing
Hide thumbs Also See for T-BERD 5800:

Advertisement

Quick Links

Quick Card
T-BERD 5800 Network Tester
DS1 PPP Ping Testing
This quick card describes how to configure and run an DS1 PPP Ping Terminate Test to validate the
provisioning and performance of T1 MPLS service.
Equipment Requirements:
• T-BERD 5800 equipped with the following:
o BERT software release V27.0 or greater
o Test options:
▪ C5E1DS1: E1/DS1 Electrical option
▪ C5DS1DS3HDLC: DS1/DS3 HDLC Analysis option
▪ C5HDLCCAPTURE: DS1/DS3 HDLC Capture
(recommended for packet capture and decode)
▪ C5DUALPORT: Dual Port option
(required on T-BERD 5800-100G only)
• One of the following T1 Cables to connect the T-BERD
DS1 Port(s) to the line under test:
o Two (2) Bantam to Bantam cables (CB-10615)
o Dual Bantam to RJ-48C cable (CB-41645)
o RJ-48C Patch cable (Straight-through or cross-over)
The following information is required to complete the test:
• T1 Framing (ESF or D4) and Line Code (B8ZS or AMI)
• Payload Type (Bulk or Fractional)
• IP Mode (Static or Auto), Source IP Address, and Subnet Mask
• User Name and Password, if service uses Authentication
• IP Addresses for PPP Server and for IP host to Ping
Connect to Line Under Test:
• The T-BERD 5800v2 has both RJ-48C and bantam ports. You may use Bantam to Bantam, Dual
Bantam to RJ-48C, RJ-48C straight through, or RJ-48C crossover cables to connect the T-BERD to
the line under test.
• The T-BERD 5800-100G has an RJ-48C port. Dual Bantam to RJ-48C, RJ-48C straight through, or
RJ-48C crossover cables may be used.
Figure 2: RJ-48C Crossover Cable
Figure 1: Equipment Requirements
Figure 3: RJ-48C Straight Through Cable
VIAVI Solutions

Advertisement

loading

Summary of Contents for Viavi T-BERD 5800

  • Page 1 Bantam to RJ-48C, RJ-48C straight through, or RJ-48C crossover cables to connect the T-BERD to the line under test. • The T-BERD 5800-100G has an RJ-48C port. Dual Bantam to RJ-48C, RJ-48C straight through, or RJ-48C crossover cables may be used.
  • Page 2 DS1/DS3►DS1►DS1 PPP► Ping►Terminate test. Note: DS1 tests must be run on Port 1 on the T-BERD 5800v2. DS1 tests must be run on Port 2 on the T-BERD 5800-100G. Figure 4: Launch Screen 3. In the Tools Panel select 4. Press to continue.
  • Page 3 Lost Pings = 0. © 2018 VIAVI Solutions Inc. Contact Us +1 844 GO VIAVI) To reach the VIAVI office nearest Product specifications and descriptions in this (+1 844 468 4284) you, visit viavisolutions.com/contacts. document are subject to change without notice.

This manual is also suitable for:

T-berd 5800v2T-berd 5800-100g