The space required must be adapted to local conditions after fitting the wheel guard and
tightening the clamping shaft.
Avoid moving the machine by the wheel guard. This may result in damage to the guard's
bearing or to the switch mechanism.
This machine must not be used in potentially explosive atmospheres.
Use anchoring bolts that fit into the machine's provided holes to ensure good anchoring
to the floor.
If the unevenness of the floor exceeds 0,25 %, sufficiently large shims may be used as
levelling material.
For a good operation it is absolutely necessary to anchor the wheel balancer to
the floor.

Electrical connection

The wheel balancer is designed to be connected to a standard 230 V/50 Hz socket.
The machine is equipped with a CE-approved plug as standard. The circuit for the
required socket must be separately fused.
Further electrical connection and reconnection work may only be carried out by a
qualified electrician in accordance with the regulations of VDE and/or the responsible
energy company. All applicable CE or DIN regulations must be observed.

Maintenance

Daily cleaning of:
Balancing flange
-
Cones
-
-
Clamping shaft
Quick-release nut
-
Distance meter
-
Monthly Maintenance:
Thorough cleaning of the machine
-
Check the electrical connection
-
Self Calibration
-
Check all machine parts for possible damage or wear.
-