  • Page 1 Arc 401 Wireless remote control Order code ! JA-WRC OPERATOR MANUAL...
  • Page 2: Product Overview

    Product Overview Overview The signal carrier remote control is designed for use with the ARC 401 series welding products. It is for use when welding at distance from the power source in construc?on, awkward welding posi?ons etc. Its main features are: • No requirement for remote control cables. The system uses the electrode lead and work return lead to send the data from the control to the power source. • The digital meter displays the welding current and arc force seHngs so that the operator can accurately pre set welding parameters • The remote control needs no addi?onal power supply. • The remote control is small, light weight, simple to operate easy to carry, with excellent performance. • The remote control can operate with cables of up to 100 metres.
  • Page 3 Controls Control panel layout 1. Indicates display is showing welding current 2. Indicates display is showing arc force setting 3. Electrode touch point 4. Adjustment minus button 5. Selection button 6. Adjustment plus button 7. Send button 8. Digital display...
  • Page 4: Installation

    Installation Connect the remote control using the magnetic back plate to the work piece (work return). Place the end off the electrode in contact with the electrode touch point (point 3 – control layout). The unit provides a modulated carrier signal The power source contains a receiving circuit for receiving and demodulating the modulated signal, and then the demodulated signal is converted to the desired welding parameter so that welding can be carried out according to...
  • Page 5 Operation Operation of the remote control Remote control operation 1. Turn on the welding power source. 1. On the remote control press the set button (point 5 – control layout) to 2. W h e n s e t t i n g t h e w e l d i n g highlight the parameter to be set, either parameters using the remote control welding current or arc force (the...
  • Page 6 7. When setting is completed remove the remote control unit and store it in a safe place. Welding can now take place. Power failure or shutdown This product has parameter memory function. Parameter settings are automatically stored even when the power is disconnected or the remote control removed.
  • Page 7: Troubleshooting And Precautions

    Troubleshooting and Precautions The most common carrier communication problems • When using the remote control at high levels, of remote control are unsuccessful communication ensure that it is secured to prevent falling to avoid or low communication rates. If these problems injury.
  • Page 8 Wireless remote control Order code !JA-WRC © Wilkinson Star Limited Issue 1 April 2014 Product is subject to change without notice...