    Intended use ......................................... 6 Unintended use ......................................6 Safety advice ......................................... 6 Disposal ........................................6 Package contents ....................................7 Summary Migma 200 ....................................7 Standard accessories ....................................7 Optional accessories ....................................7 Technical data ....................................... 7 Installation at customer ..................................8 Dispatch and packaging for carriage ................................
  • Page 3: Notes

    Mikrona Technologie AG is only liable if mounting, readjustment and repairs are performed by Mikrona or an entity authorized for this pur- pose by Mikrona Technologie AG and if the product is used in accor- dance with the instruction manual.
  • Page 4: General Safety Instructions

    The operator / user must be familiarized with the operation of the de- vice. Rating plate The rating plate of the table-top model Migma 200 is placed on the back of the device. You may always state the device number when reporting defects or...
  • Page 5: Labeling Of Warning And Risk Phrases

    The symbol “maintenance” labels information and sections referring to repair work which is beyond normal maintenance and is to be carried out by qualified specialists or by Mikrona’s customer service. Notes on the instruction manual Read through the instruction manual and maintenance recommen- dations before using the device.
  • Page 6: Product Information

    The device and its accessories are planned for the mixing of impres- sion compounds. Another use beyond that is considered unintended. Mikrona Technologie AG assumes no liability for damages caused by unintended use. The operator himself bears the risk. Safety advice...
  • Page 7: Package Contents

    All functions are easily operated and quality material distinguish Mig- ma 200, thus creating a low-maintenance and durable device. Its fine surfaces are easy to clean. In order to save space, Migma 200 can also be integrated into furnishing as built-in model.
  • Page 8: Installation At Customer

    MIGMA 200 Instruction Manual 5. Installation at customer Dispatch and packaging For each transport (by rail, road, air etc.) the device may be attached for carriage to the base plate with the safety screws for carriage. This serves to pro tect the device form sudden jerky impacts.
  • Page 9: Mixing Alginate

    Instruction Manual Mixing alginate Set the desired mixing time from the scale of 4-28 seconds. Alginates are usually mixed during 10-12 seconds. Mixing time, water amount and water temperature have influence on the segregation time. Dose the alginate as suggested by the manufacturer and fill it into the mixing bowl.
  • Page 10: Mixing Polyether Or Silicon Impression Compounds

    MIGMA 200 Instruction Manual Mixing polyether or Set the desired mixing time from the scale of 4-28 seconds. Polyether silicon impression and silicon impression compounds are usually mixed during 20-28 compounds seconds. Mixing time depends on the viscosity of the mixture.
  • Page 11: Mixing Other Material

    Instruction Manual Mixing other material The mixing device MIGMA 200 can also be used to mix other materials (low viscosity), such as - resin - glue - etc. Follow the manufacturer’s processing instructions. Identify mixing time, mixing ratio and mixing amount for ideal results.
  • Page 12: Safety Shutdown

    Make sure that no fluids enter the inside of the device as this may lead to irreparable damage. Disinfection For disinfection use generally mild surface disinfectants without any alcohol or aldehyde added. Suitable and approved for MIGMA 200 are the following products: FD 312 Dürr Dental, DE-Bietigheim FD 366 sensitive Dürr Dental, DE-Bietigheim...
  • Page 13: Troubleshooting

    Instruction Manual 10. Troubleshooting 10.1 Errors Cause Solution Too much water added Dose water according to manufacturer’s in- Compound is too fluid after mixing struction with measuring cup or dosing bottle Insufficient mixture quality, Not enough water Dose water according to manufacturer’s in- uncombined alginate struction with measuring cup or dosing bottle Short mixing time...
  • Page 14: Technical Error

    This part of the operating instructions is to provide assistance to tech- ni cians of specialized dealers in particular. If an error cannot be loca- lized by troubleshooting, a technician authorized by Mikrona or Mikro- na’s customer service is to be commissioned for resolution.
  • Page 15: Accessories

    Please consider that user / operator safety and failure-free operation of the device is only provided when using original components. Only use accessories that are listed in the instruction manual or authorized by Mikrona for this particular purpose. 430.2010.02...
  • Page 16 MIKRONA TECHNOLOGIE AG Wiesenstrasse 36 | 8952 Schlieren | Switzerland P +41 56 418 45 45 | swiss@mikrona.com | www.mikrona.com...

Table of Contents