Kolmeks L Series Manual

Centrifugal pumps

Advertisement

Quick Links

CENTRIFUGAL PUMPS
SERIES
L_
AL_
T
AT
AKN_
AS_
KL
KN_
N_
INSTRUCTION MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the L Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Kolmeks L Series

  • Page 1 CENTRIFUGAL PUMPS SERIES AKN_ INSTRUCTION MANUAL...
  • Page 2 TYPE dB(A) TECHNICAL DATA L_/T r/min kW A (400V) TYPE dB(A) L_/T r/min kW A (400V) 3000 30.5 3000 18.5 32A/4 1500 0.05 0.21 3000 1500 0.08 0.28 3000 3000 0.25 0.70 3000 3000 0.65 1.80 3000 77.5 40A/4 1500 0.60 125S/4 1500 18.5 34.00...
  • Page 3 TYPE dB(A) TYPE dB(A) AL_/AT r/min A (400V) AL_ AT r/min A (400V) 1154/6 1000 12.70 32-160/2 3000 1.5 3.30 /4 1500 3000 2.2 4.70 1500 11.90 32-200/2 3000 6.40 1500 15.70 3000 8.20 1500 22.60 3000 5.5 11.00 1500 31.00 40-160/2 3000...
  • Page 4 DESIGN AND FUNCTION The pump and motor constitute a unit, where the rotating parts of both the pump and the motor are on the same shaft (mono-block construction). The motor is of a dry construction and its bea- rings work at the same time as bearings for the whole pump. Motor: Fully-enclosed A.C.
  • Page 5 The nominal pressure and the max. temperature of pumped liquid are stamped on the pump data plate. Never use the pump in any other application or conditions without manufacturer’s acceptance. In the case of damage there may be danger to persons by having poisoning, burns, wounds etc.
  • Page 6 All electrical work shall be carried out by an electrician approved by the power supplier. Check, that the voltage on the pump data plate corresponds to the mains voltage. Standard connections: Smaller motors (below 4 kW) Bigger motors A starter must always be used and should be an ordinary motor protection breaker. Make ATTN sure that the overload protection is set no higher than the rated current specifi...
  • Page 7 The motor is equipped with ball bearings which are lubricated for life and therefore do not need any service. In the case of any motor malfunction it is recommended to replace the whole motor unit. In the twin pump installation it is possible to substitute the damaged unit by a blind cap (to be ordered separately).
  • Page 8 O-RING SEALING FLANGE 56-57 WEARING RING (N_-SERIE) SCREW SCREW OR NUT WASHER DECLARATION OF CONFORMITY OY KOLMEKS AB P.O.Box 27 FI-14201 Turenki declare under our sole responsibility that the products - SERIE - SERIE - SERIE - SERIE AKN_ - SERIE...

This manual is also suitable for:

Al seriesT seriesAt seriesAkn seriesAs seriesKn series ... Show all