General notes Kolmeks pumps do not require regular service. The pump shaft seal is a mechanical seal (not used in wet motor pumps). It is a part which undergoes wear and which must be replaced if it starts to leak. Please note that a leakage of a few drops per hour can be quite normal, especially when pumping water-glycol mixtures.
Screw (AT- and T-series) series) Screw 24 Nut / Screw Pipe joint (AMK-25,-26, 25 Washer AHV-25, AE-26,-33, AP-33) 26 Key 80/81 Pipe joint (ALH-series) Pipe (ALH-series) Flap device (AT- and T-series) Pin (AT- and T-series) www.kolmeks.com 04/2013 Subject to change without prior notice.
Page 4
6) Connect the motor cable and open the valves. Start the pump and check the di- rection of rotation. Vent the system. Monitor the opera- tion of the pump. www.kolmeks..com 04/2013 Subject to change without prior notice.
Page 5
6) Connect the motor cable and open the valves. Start the pump and check the di- rection of rotation. Vent the system. Monitor the opera- tion of the pump. www.kolmeks.com 04/2013 Subject to change without prior notice.
Page 6
7) Install a new impeller. 8) Attach the motor unit If required, you can lightly as usual. tap the impeller with a rubber mallet until flush with the ridge. Tighten the screw/bolt of the impeller. www.kolmeks..com 04/2013 Subject to change without prior notice.
Page 7
Check the housing and O-ring groove for the stationary ring in the sealing flange are clean. Check the O-ring and lubricate it with soap water, not with oil. Then install the O-ring in the groove of the sealing flange (in the stationary ring for BO- and BP-marked seals). www.kolmeks.com 04/2013 Subject to change without prior notice.
Page 8
Install the sealing flange onto the motor. Place the assembly sleeve of the installation tool so that it forms a shaft extension. In large pumps, first install the sealing flange onto the motor and then the stationary ring (BO- and BP-marked seals). www.kolmeks..com 04/2013 Subject to change without prior notice.
Page 9
Lubricate the shaft and the seal elastomer bellows suitably with soapy water, not with oil. www.kolmeks.com 04/2013 Subject to change without prior notice.
Page 10
Do not touch the rotating surface of the rotating ring. Installing spring, back plate and impeller Rotate the shaft sligtly and carefully and ensure that the seal fits well. Then, install spring, back plate (if separate) and impeller. www.kolmeks..com 04/2013 Subject to change without prior notice.