Download Print this page
Aktobis WDH-310EKW Quick Start Manual
Hide thumbs Also See for WDH-310EKW:

Advertisement

Quick Links

Dehumidifier WDH-310EKW
Dear Customer,
You have chosen a high-quality product. To ensure that you get a lot of enjoyment from this product, here are a few
more tips:
After transport:
Since the unit works with refrigerant, improper transport can sometimes occur despite careful instructions on the
carton. For this reason, we ask you to leave the unit upright for at least 4 hours before using it for the first time.
4 hours before using the unit for the first time, so that the refrigerant can settle properly in the unit.
In case of any problems:
We hope that the unit meets your expectations! If, despite the greatest possible care, there should ever be cause
for complaint, please contact us briefly, as we are very concerned about your satisfaction and would like to clear up
any misunderstanding.
Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany
www.AKTOBIS.de
Email: info@aktobis.de

Advertisement

loading
Need help?

Need help?

Do you have a question about the WDH-310EKW and is the answer not in the manual?

Questions and answers

Summary of Contents for Aktobis WDH-310EKW

  • Page 1 We hope that the unit meets your expectations! If, despite the greatest possible care, there should ever be cause for complaint, please contact us briefly, as we are very concerned about your satisfaction and would like to clear up any misunderstanding. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 2 8 years. Do not make any changes to the unit ! The dehumidifier should not be operated or stored in a room with other burning/heating appliances ! Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 3  The unit must be installed according to the national installation regulations.  Do not use any objects, except those permitted by the manufacturer, to accelerate the defrosting process.  Do not drill or burn. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 4 If hot work is to be carried out on the refrigerant equipment or associated parts, suitable fire extinguishing equipment must be readily available. Make sure that a dry powder fire extinguisher or a CO2 fire extinguisher is nearby. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 5 Make sure that gaskets or sealing material are not so worn that they no longer serve their purpose in preventing the ingress of flammable atmospheres. Spare parts must be in accordance with the manufacturer's specifications. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 6 The following procedure should be followed: - Remove the refrigerant - Purge the circuit with inert gas - Deflate - Rinse again with inert gas - Open the circuit by cutting or soldering Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 7 (k) Reconditioned refrigerant shall not be charged into other refrigeration systems unless it has been purified and tested. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 8 When draining oil from a system, this must be done in a safe manner. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 9: Functional Description

    2.) Fan strength button (Low / High) 6.) Display screen 7.) „Condensation tank full" signal light 3.) Timer button (From 1-24 hours) 4.) (Humidity) setting buttons 8.) Defrost light (unit in defrost mode) Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 10 On/Off button for 5 seconds until you hear a tone confirming the activation. The unit should now be switched on and the signal light should also flash again. The WLAN function is active again. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 11 3.4. Proper drainage of condensation water with hose connection ! Make sure that the hose always has a slight slope (see the following diagrams). Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 12 It is best to clean the air filter carefully under lukewarm water or with a low-setting (suction power) hoover. Push the cleaned air filter back into its holder from above - DONE. Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de...
  • Page 13: Technical Data

    All data are approximate per day (fluctuation tolerance) when measured directly at the unit inlet and, of course, these values only apply if the temperature and moisture content remain constant! Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 14 Damage due to external influences, use of force or foreign objects Damage caused by non-observance of the operating instructions, e.g. connection to an incorrect mains voltage or non-observance of the assembly instructions. Completely or partially dismantled units Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...
  • Page 15 They will then recycle the appliance. I wish you much pleasure with this appliance. Keep these instructions for use in a safe place ! Aktobis AG, Borsigstr. 20, D-63110 Rodgau / Germany www.AKTOBIS.de Email: info@aktobis.de...