  • Page 2 WARNING WARNING Only install and operate this appliance as outlined in this instruction manual. At all Only install and operate this appliance as outlined in this instruction manual. At all times,use care when using this appliance. times,use care when using this appliance. Do not modify this appliance in any way to avoid danger.
  • Page 3 WARNING Additional warnings for appliances with R290 refrigerant gas (refer to the rating plate for the type of refrigerant gas used) READ THE MANUAL CAREFULLY BEFORE USING THE APPLIANCE R290 refrigerant gas complies with European environmental directives, This appliance contains a pproximately 0.115 kg of R290 refrigerant gas. The maximum refrigerant charge amount is 0.3 kg;...
  • Page 4 WARNING WARNING Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer. The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater.
  • Page 5 INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 1.Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
  • Page 6 INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 - the ventilation machinery and outlets are operating adequately and are not obstructed; 8.Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with.
  • Page 7 INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 12.Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
  • Page 8 INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 amount of refrigerant contained in them. - Cylinders shall be kept upright. - Ensure that the refrigeration system is earthed prior to charging the system with refrigerant. - Label the system when charging is complete (if not already). - Extreme care shall be taken not to overfill the refrigeration system.
  • Page 9 INSTRUCTION FOR REPAIRING APPLIANCES CONTAINING R 290 for the recovery of refrigerant). Cylinders shall be complete with pressure relief valve and associated shut-off valves in good working order. Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs. The recovery equipment shall be in good working order with a set of instructions concerning the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants.
  • Page 16: Specifications

    SPECIFICATIONS MODEL WDH-520EB POWER 220-240V~50Hz VOLTAGE/FREQUENCY 505 W 20L / D CAPACITY (30°C,80%RH) REFRIGERANT R290 / 0.115 kg SIZE OF SHELL ( W H D ) 345*621*261 mm × × 12.9kg WEIGHT OPERA TING TEMPERATURE 5 ℃ ~ 32℃ T1A.L 250V FUSE Waste electrical products should not be disposed of with household waste.