If a hood cannot be installed, an electric extractor fan must be fitted to the outside wall or the
window.
This electric extractor fan must have a sufficient capacity to guarantee a change of air of the
kitchen of at least 3-5 times its volume.
Components shown in fig. 4
A : Opening for air supply
C : Hood for exhaust removal of combustion fumes
E : Electric extractor fan for removal of combustion fumes
Connection to gas supply
)
Before installation, make sure the type and pressure of the local gas supply are
compatible with the cooktop settings. To do this, check the data on the appliance data
plate on the cooktop as well as on this handbook.
The gas connection must be carried out by a qualified technician in compliance with local current
regulations.
If using metal hoses, ensure these do not come into contact with any movable parts and are at no
point crushed.
Carry out the connection in such a way as does not cause any stress whatsoever on the appliance.
The gas supply connector is threaded G½".
For ISO R7 connections, the gasket is not required.
For ISO R228 connections, the washer supplied must be fitted.
)
After connection operations, check for leaks using a soapy solution.
Electrical connection (Fig. 44)
Before connecting the appliance to the electricity supply, check that the voltage corresponds to that
on the data plate and that the power supply cable is suitable for the appliance load also stated on
the data plate.
If the appliance is connected directly to the mains, fit an all-pole disconnect switch with minimum
contact gap of 3 mm, adequate for the appliance load and complying to regulations.
)
Do not use reducers, adapters or switches for connection to the mains, since these
could overheat and cause burns.
)
Regulations require that the appliance is earthed. The manufacturer declines all liability
resulting from failure to observe this regulation.
If the power cable must be replaced, use a cable having identical characteristics to the original
supplied by the manufacturer, suitable for the load and temperature (type T90°C). This is available
from After-sales service. Furthermore, the end of the power cable to be connected to the appliance
must have the Yellow-Green earth conductor 20 mm longer than the other conductors.
Refer to the table below for the size of the power cable
Type of cooktop
Only gas burners
With electric power up to 1000W
With electric power above 1000W
ADJUSTMENT TO DIFFERENT TYPES OF GAS
If a different type of gas from the one indicated on the rating plate is used, the injectors must be
replaced.
If spare injectors are not supplied with the appliance, they are available from the After-sales
service.
For the choice of replacement injectors, refer to the injectors table.
The injectors are identified by their diameter, which is expressed in hundredths of mm, stamped on
the body of the injector itself.
Size
2
3X0.50 mm
2
3 X 0.75 mm
2
3 X 1.5 mm
8