Download Print this page

Seco VINCO 600 Manual

Advertisement

Quick Links

www.seco.gr
R
Tel. 0030 210 9846222
Fax 0030 210 9822276
Agiou Dimitriou 263, TK. 17342, Athens, Greece
Sliding Gate Opener
MANUAL
ENG
GR
VINCO
600 - 800 - 1000 - 1500 - 2000 - 2500

Advertisement

loading

Summary of Contents for Seco VINCO 600

  • Page 1 Tel. 0030 210 9846222 Fax 0030 210 9822276 Agiou Dimitriou 263, TK. 17342, Athens, Greece Sliding Gate Opener MANUAL VINCO 600 - 800 - 1000 - 1500 - 2000 - 2500...
  • Page 2 VINCO Sliding Gate Opener Safety Protection and Precautions THIS SERIES OF DOOR OPENERS MUST BE INSTALLED BY PROFESSIONALS. ATTENTION! Please operate the machine carefully in strict compliance with instructions of this Manual. It is very important to personal safety . Incorrect installation or improper use of the machine may cause serious damage to the person and/or property.
  • Page 3: Main Technical Specifications

    Tel. 0030 210 9846222 Fax 0030 210 9822276 Agiou Dimitriou 263, TK. 17342, Athens, Greece Main Technical Specifications: MODEL VINCO 600 VINCO 800 VINCO 1000 Supply Voltage(V) AC230/120V AC230/120V AC230/120V Motor Power(W) 280W 370W 550W Torque 20Nm 20Nm 20Nm...
  • Page 4: Mount The Rack

    SC - SDCB102 Control Panel for Sliding Gate Motors Mount the Rack The easiest way to install a rack is to place it on the gear teeth of the door opener first, disengage the door opener, and then push the door slowly to move the tack bit by bit to the desired position.
  • Page 5: Care And Maintenance

    Tel. 0030 210 9846222 Fax 0030 210 9822276 Agiou Dimitriou 263, TK. 17342, Athens, Greece For wiring, see Fig. 6 For control panel wiring, see Control Panel Manual. Energizing & Trial Run Before use, check the power supply voltage, frequency and other data carefully and make sure they are in line with the requirements, and check if the ground wire is in good condition and the electrical wiring is correct.
  • Page 6: Possible Faults And Trouble Shooting

    Possible Faults and Trouble shooting Fault Possible Causes Troubleshooting No power supply. Check the power supply. Fuse is blown. Replace the fuse. Capacitor breaks down. Replace the capacitor. Check for any obstruction on Overloaded. Motor cannot be started. the door rail. Thermal protector is activated.