E54
Voltage value on the motor circuit even when the same should not be operating
Measure between all the terminals of the
wiring connector J11-1 ÷ J11-5 and the
appliance body - see page 47 - point 3
Is there any dispersion?- (see Fig. 6) -
YES
Detach the connector from the motor and
measure between the terminals and the
motor casing.-(see Fig. 10) -
Is there any dispersion?
YES
Replace the motor and repeat the
diagnostic cycle to check for any further
alarms.
MAIN CIRCUIT
BOARD
Technical Support - A.D.L.
E54: Motor relay contacts sticking
Fig. 10
!
Check that all the connectors are correctly inserted
Replace the circuit board and repeat the
diagnostic cycle to check for any further
NO
Check/replace the wiring and repeat the
diagnostic cycle to check for any further
NO
Fig. 4
General
earthing
connection
!
50/70
alarms.
alarms.
If there are burns on the circuit board,
see page 68