28 EEPROM LAYOUT (HANDSET)

28.1. Scope

The purpose of this section is to describe "the layout of the EEPROM (IC2) for the KX-A144 Handset".
The EEPROM contains hardware, software, and user specific parameters. Some parameters are set during production of the
handset e.g. crystal oscillator adjustment at 0000..01, some are set by the user when configuring the handset e.g. ringer volume
at 0F3E, and some during normal use of the phone.

28.2. Introduction

The handset uses a 32k bit serial EEPROM (IC2) for storing volatile parameters. All parameters are set up before the handset
the factory. Some of these are vital for the operation of the hardware so a set of default parameters is programmed before the
actual hardware fine-tuning can be initiated. This document lists all default settings with a short description.
This document lists all default parameters with a short description.
In the tables below values in a range that are similar are not repeated; i.e. Address 00 to 01 contains the value 00 simply means
that the value 00 is repeated in all addressee in the range.
Type
Name
D
default
A
adjust
-
Country
x
Setting

28.3. EEPROM contents

28.3.1. General Setup
Address
Default
0000-0001
00 60
0002
0A
0030-0034
00
0036-003A
-
003B-003F
-
0040-0044
-
0045-0049
-
004A-004D
FF
0100-0104
-
0105
-
0106
-
0107
-
0108-0114
-
0115
-
0116
-
0117-126
-
0130-134
-
0135
-
0136
-
0137
-
0138-0144
-
0145
-
0146
-
0147-0156
-
0160-0164
-
0165
-
0166
-
0167
-
0168-0174
-
0175
-
0176
-
0177-0186
-
Description
The EEPROM location is preset to the Default value by the eeprom default loader.
The EEPROM location is set during the production test and should not be overwritten. The value is set by
the eeprom default loader only if the location contains 0xFF, i, e. it has never been set.
EEPROM location which is not set at all.
Default - no specific country setting, so revert to default value
Name
Country
Setting
EepromOscillator
ModulationDeviation
IPEI (ID for Handset)
PARK_1 (ID for Base 1)
PARK_2 (ID for Base 2)
PARK_3 (ID for Base 3)
PARK_4 (ID for Base 4)
PLI_1-PLI_4
RFPI_1 (Base 1)
SerClass_1
LAL_1
IPUI_LEN_1
IPUI_1
ZAP_1
STATUS_1
UAK_1
RFPI_2 (Base 2)
SerClass_2
LAL_2
IPUI_LEN_2
IPUI_2
ZAP_2
STATUS_2
UAK_2
RFPI_3 (Base 3)
SerClass_3
LAL_3
IPUI_LEN_3
IPUI_3
ZAP_3
STATUS_3
UAK_3
KX-TCD445BXS / KX-TCD445BXT / KX-TCD445BXF / KX-A144BXS / KX-A144BXT / KX-A144BXF /
Type
Description
-
A
Frequency adjustment
-
A
Mudulation adjustment
-
A
IPEI
-
-
PARK for registration 1
-
-
PARK for registration 2
-
-
PARK for registration 3
-
-
PARK for registration 4
-
D
Pli for registration 1-4. If set to FF the registration is
deleted.
-
-
RFPI for registration 1
-
-
Service class for registration 1
-
-
Location area level for registration 1
-
-
IPUI length for registration 1
-
-
IPUI for registration 1
-
-
ZAP for registration 1
-
-
Status for registration 1
-
-
UAK for registration 1
-
-
RFPI for registration 2
-
-
Service class for registration 2
-
-
Location area level for registration 2
-
-
IPUI length for registration 2
-
-
IPUI for registration 2
-
-
ZAP for registration 2
-
-
Status for registration 2
-
-
UAK for registration 2
-
-
RFPI for registration 3
-
-
Service class for registration 3
-
-
Location area level for registration 3
-
-
IPUI length for registration 3
-
-
IPUI for registration 3
-
-
ZAP for registration 3
-
-
status for registration 3
-
-
UAK for registration 3