Download Print this page

Cardinal Satellite Series Technical And Operating Manual page 18

Unattended weighing kiosk

Advertisement

The 225 ID Storage feature has been designed to control three different types of transactions
and weighing operations. The first type of transaction assigns a permanent ID string, has a
stored tare weight, and accumulates net weight totals for the ID. The second type assigns a
permanent ID string and accumulates net weight totals for the ID, but does not have a
permanent stored weight. The third type temporarily assigns an ID string (while weighing in)
and does not accumulate any net weight totals for the ID.
PERMANENT
Single Pass Transaction (One-Step Operation)
The first type of permanent transaction is a "single pass" transaction and is used to
weigh loaded containers with a permanent ID string and a previously stored tare weight.
The stored tare weight requires weighing the empty container in advance or if the
weight of the empty container is known, by entering that value as a manual tare weight.
The single pass transaction completes a ticket and accumulates the net weight for the
ID associated with the container with a "one-step" weighing operation.
Two Pass Transaction (Two Step Operation)
The second type of permanent transaction is a "two pass" transaction and is used to
weigh the loaded container once when it is empty and once when it is loaded. A
permanent ID string and a previously stored zero (0) tare weight is required. In the two
pass transaction, the zero tare weight is replace by the new tare weight after the first
pass and returned to zero after the second pass when the transaction has been
completed. The two pass transaction requires a "two-step" weighing operation. On the
first step, the incoming weight will be stored and an interim ticket will be printed. On the
second step, during the outgoing transaction, a complete ticket will be printed and the
net weight for the ID associated with the container will be added to the accumulator.
TEMPORARY
Two Pass Transaction (Two Step Operation)
The third type is a temporary "two pass" transaction that also requires a "two-step"
operation. However, the ID string is only in memory while the container is weighed in
and out and the net weight will not be accumulated. In this type of transaction, on the
first pass, the container will be placed on the scale and an ID will be selected either by
the operator entering an ID string or by the indicator automatically assigning the ID
string. The weight will be stored and an interim ticket will be printed. On the second
pass, the ID string is entered and the stored weight is recalled for printing the complete
ticket. After the ticket has printed, the ID number and the stored weight will be removed
from memory.
8545-0964-0M Rev A  Satellite Series Technical and Operation
14
225 ID STORAGE OPERATION

Advertisement

loading