6 Pin terminal description

Pluggable 6P terminal set: In the case of limited space, the terminal can be pulled out at any
time to facilitate the connection of the wire, and then re-insert it
Wire size: at least 0.75mm
"T-T" : The main battery temperature sensor connection terminal, the sensor can
be connected at will regardless of the positive and negative poles. The
temperature compensation value is: -3mV/℃ /2V. The temperature sensor
is an optional accessory, if not connected, the controller defaults to the
battery temperature at 25°C.
Note: Lithium batteries do not have temperature compensation
"Ss-, Ss+": Used to connect cables for accurately measuring the battery voltage,
which helps the controller to more accurately determine the current
battery Voltage. Compensate for the voltage loss on the charging cable.
If the voltage sensor is not connected or the connection is interrupted,
It will switch to the normal operation of the measurement program with
the charging cable, which does not affect the normal operation of the
charger. If there are multiple batteries To use in parallel, connect SS- to
the negative terminal of the first battery, and connect SS+ to the second or
last battery The positive pole
"TR":
Only B2B/BS12V-12V series have this function, which is mainly used in
occasions that require high current, such as in the automobile industry.
During driving, an inverter needs to be used to supply power to the car air
conditioner. The "TR" terminal can control the start battery and production
A relay between the active batteries is the parallel connection of the
starting battery and the living battery. Increase the starting battery
capacity
"D+"
B2B charging control signal, connect "D+" directly to the D+ signal output
terminal of the
can be directly connected to the car ignition switch ON signal to Instead
of the D+ signal on the a
the B2B charging will not work
Temperature sensor (RTS)
Connect the temperature sensor to the "T T" port, and connect the other end to the main battery
to measure the real-time temperature of the main battery, ensure the temperature the
connection position of the sensor is not interfered by any heat source (including motor heat,
exhaust gas, heater, etc.), when the temperature sensor is not connectedOr when the
temperature sensor is disconnected, the controller will automatically switch to the default 25℃.
The lithium battery has no temperature compensation function, so there is no need to connect
a temperature sensor.
2
. If there is no D+ signal in a
a
lternator
lternator
, if the D+ terminal is not connected,
, the "D+"
lternator

Advertisement