Electrical Connections - Huawei SUN2000-36KTL Quick Manual

Hide thumbs Also See for SUN2000-36KTL:
Table of Contents

Advertisement

4

Electrical Connections

4.1
Preparations
NOTE
1. Before connecting cables, ensure that all required OT terminals and cables are prepared.
2. The SUN2000-42KTL supports the 3W+PE wiring mode.
3. The SUN2000-36KTL supports 3W+PE and 3W+N+PE wiring modes. Connect the neutral wire
if required.
No.
Name
1
OT terminal
2
OT terminal
3
Ground cable
4
AC output power
cable
5
DC input power
cable
6
RS485
communications
cable
7
FE
communications
4.2
cable
8
Cable tie
Model or
Specifications
M6
M8
Outdoor copper-core
cable with a cross-
sectional area of 16
mm
2
Outdoor copper-core
cable with a cross-
sectional area of 25
mm
2
PV1-F/4 mm
2
Computer cable
DJYP2VP2-22 2x2x1
Outdoor shielded
network cable CAT 5E
Outdoor shielded
network cable CAT 5E
N/A
4
Quantity
Function
1 PCS
Connects to a ground
cable.
3 PCS
Connects to an AC
output power cable.
N/A
Connects to a ground
cable.
N/A
Connects to an AC
output power cable.
N/A
Connects to a DC input
power cable.
N/A
Connects to an RS485
communications cable
over a terminal block.
N/A
Connects to an RS485
communications cable
over an RJ45 network
port.
N/A
Connects to an
Ethernet
communications cable
over an FE network
port.
Based on site
Binds cables.
requirements

Advertisement