Elterm Captain Operating And Assembly Manual

Elterm Captain Operating And Assembly Manual

Electric tankless water heater for central heating systems (electric heating boiler)

Advertisement

Operating and assembly manual: electric tankless water
heater for central heating systems (Electric heating boiler)
Advanced series:
Captain
(AsBN-W)
Colonel
(AsZN-W)
Marshal
(AsDC-W)
Lieutenant
(AsC-W)
Mobil PRO
(AsMB PRO)
Industrial series:
Commander
(AsHN)
Division
(AsB IV)
Mobil Stark
Please see video prior installation
Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno
1
www.elterm.pl

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Captain and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elterm Captain

  • Page 1 (Electric heating boiler) Advanced series: Captain (AsBN-W) Colonel (AsZN-W) Marshal (AsDC-W) Lieutenant (AsC-W) Mobil PRO (AsMB PRO) Industrial series: Commander (AsHN) Division (AsB IV) Mobil Stark Please see video prior installation Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 2 Mobil Lieutenant (AsDC-W) (AsMB PRO) (AsC-W) 6 -24kW – 156x46x46cm 4-24kW (30-48kW Stark) 4-12kW – 70x54x27cm Commander Division (AsHN) (AsB IV) 4-12kW – 68x37x21cm 15-24kW – 68x41x24cm 30 -48kW – 68x41x27cm Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 3 Captain, Colonel, Commander Captain, Colonel, Commander Marshal power 4-12kW power 15-24kW power 6-24kW Lieutenant Division, Mobil Stark 30-48kW power 4-12kW (CH) / 12-21kW (DHW) Mobil PRO 4-24kW Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 4 5 x 25 5 x 50 5 x 70 5 x 120 * The exact cross-section of the power cord is selected by an electrician based on an analysis of local conditions. Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 5: Hydraulic Assembly

    (closed systems) or applicable regulations valid in the country of installation. Central heating system has to be thoroughly flushed prior installation. Heating installation should be flushed prior use and filled with water or anti-freeze fluid (1,5 bar). Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 6: Electrical Assembly

    In order to prevent increased components wear and unnecessarily inflated electricity bills - bridge needs to be replaced with wired or wireless, voltage free (zero Volt) room temperature controller as soon as possible. Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 7: Control Panel

    17. Function buttons (symbols ← → ↑ ↓ ) 18. ON/OFF + return button 19. Green diode – boiler turned on 20. Red diode – boiler turned off 21. Choose button 22. Internet module connection icon Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 8 ←, using ↑↓ choose either CH or DHW (D). Press to enter temperature setting (E)(F), then using ↑↓ increase or decrease parameter value. The choice is set by pressing Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 9 1.6. Hysteresis CWU 1.7. Default settings 1.8. Room programs 1.9. DHW programs 1.10. Circulation pump 1.11. Circulation time 1.12. Calibration 1.13. Internet 1.14. Max power 1.15. Battery (cascade operation) Energy consumption Venting Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 10 (YES), ↑ activate settings. - confirm choice. Default settings DHW temperature 50°C CH sections ...................... CH temperature 50°C PID-P ........................... Power 100% CH hysteresis ..........................DHW sections DHW hysteresis ....................Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 11 (C) and enter SETTINGS (J), then choose Circulation pump and press once more. Using ←→ switch between parameters (weekdays, working time, temperature, status), using ↑↓ change parameter value, which is then set by pressing Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 12 D.H.W./C.H. options (d). Using ↑↓ change parameter value- ON/OFF (e), which is then set by pressing Elterm boilers are equipped in AntiStop function. Automatics turns the pump on for one minute once every 14 days, what prevents it's rotor from seizing. AntiStop operates independently from on/off mode. It is...
  • Page 13 NOTES ............................................................................................................................................................................................................................................................................................................................................................................For more information please visit www.elterm.pl Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 14 42kW, 45kW, 48kW and boiler cascades 1,5MW (each boiler up to 48kW) Models: AsPC, AsP, AsBN, AsZN, AsD, AsC, AsBI, AsBN-W, AsZN-W, AsD-W, AsC-W, AsDC-W, AsBII, AsHZ, AsHN, AsBIII, AsBIV, AsMB , manufactured at the Elterm production plant, are in conformity with the applicable provisions of the following EC Directives:...
  • Page 15: Boiler Model

    Full name and address of the boiler owner …………………………….…………………………………………………………………………………………………………………………… …………………………….…………………………………………………………………………………………………………………………… Postal code, town /Boiler owner tel. no Postal code, town /Boiler owner tel. no …………………………….………………………………………… ………………………………………………………… …………………………….………………………………………… ………………………………………………………… Production date Boiler serial no. Production date Boiler serial no. Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...
  • Page 16 Elterm - leading Polish manufacturer of comprehensive heating solutions! Elterm M.M.Kaszuba Sp.J., ul. Przemysłowa 5, 86-200 Chełmno www.elterm.pl...

Table of Contents