4. TROUBLE SHOOTING
4.9.2 Slide Trouble (ON/OFF)
LGE Internal Use Only
START
The all paths connected
to U100 are OK?
YES
Is the VRIO a 1.8V?
YES
Folder signal is low on
Magnetizing into U100?
YES
The DBB(U103) is broken.
Change the board.
- 92 -
NO
Re-solder the
C103, C104
NO
Refer to Power ON
Trouble
NO
Replace the U100.
The U100 is broken