Original operating manual ORIGINAL OPERATION MANUAL Legal notice Copyright All rights to this manual and its attachments lie with Rosenbauer International AG. The documents are only entrusted to the recipient for their personal use. Reproduction, reprinting (electronically or mechanically), translations in other languages or all other duplication, also of parts of the manual, are only allowed with written permission.
Declaration of conformity Declaration of conformity RS 14 EFI According to EC Machinery Directive 2006/42/EC, Annex II, part 1A Herewith declares Rosenbauer International AG Fire fighting technology A - 4060 Leonding, Paschinger Str. 90 Address: Postbox 176, 4021 Linz, Austria...
Page 7
Declaration of conformity Declaration of conformity RS 14 SUPER SILENT EFI Fire fighting technology A - 4060 Leonding, Paschinger Str. 90 Address: Postbox 176, 4021 Linz, Austria Telephone: +43 (0)732 / 6794-0 that the Power generator Type RS 14 SUPER SILENT EFI Serial number A0516 complies with the following regulations:...
If this manual contains a technical error or a typographical error, Rosenbauer reserves the right to make change at any time and without no- tice. This manual may contains figures and descriptions, that are not built into the delivered product.
Page 9
Introduction Identification RS 14 EFI power generator: RS 14 SUPER SILENT EFI power generator: ► Enter the serial number of the power generator into the table. 9 / 89...
Introduction Use of the operation manual Use of the operation manual 3.4.1 Validity This manual contains information needed for the operation of the product. This manual contains descriptions of special equipment as well as some abstractions and exemplary illustrations. The actual equipping of your prod- uct may therefore differ in part from the descriptions and illustrations.
Page 11
Introduction Use of the operation manual WARNING! This symbol warns of a dangerous situation, in which non-observation of the danger warning can lead to death or serious irreversible injury. CAUTION! This symbol warns of a dangerous situation, in which non-observation of the danger warning can lead to slight reversible injury.
Improper use of the product can result in personal injury. Additionally, the product or other material assets of value may be damaged. Rosenbauer can warrant the safety, reliability and performance of its prod- uct only if the product is used in accordance with the stipulations in this manual.
Page 13
Safety Other regulations In addition to this manual the relevant national legislation, regulations and directives in the latest version are to be observed (e.g. guidelines for per- sonal protective equipment, road traffic regulations, country-specific train- ing regulations for the fire department, accident prevention guidelines, fire department duty regulations, occupational medicine and technical environ- mental rules, country legislation for fire and disaster protection).
Personnel must exhibit physical and mental aptitude. Minors and persons without firefighting training may not operate the product. Modifications and conversions to the product may be performed only with written authorization from Rosenbauer and must be performed by a manu- facturer-authorised person. 14 / 89...
Observe the operation and maintenance manuals of additional products. If you cannot fix faults yourself or repairs could not be carried out by spe- cially trained workshop personnel, Rosenbauer or the nearest Rosenbauer service partner must be contacted immediately. 15 / 89...
Safety List of the safety symbols used List of the safety symbols used 4.6.1 Meaning of the warning signs Danger from electricity. Impending fire risk. Impending risk of explosion. Risk from oxidising materials. Risk of harmful or irritating materials. Impending risk of explosion. Impending acid burn risk.
Page 17
Safety List of the safety symbols used Impending crushing risk. Threat of environmental contamination. Threat of shearing. 17 / 89...
Safety List of the safety symbols used 4.6.2 Meaning of the prohibitory signs Handling fire and naked flames forbidden! Do not touch or reach in! Do not stay in the danger area! 18 / 89...
Safety List of the safety symbols used 4.6.3 Meaning of the caution signs Use hearing protection. Wear a protective helmet. Wear a protective suit. Maintain distance. Special caution. 19 / 89...
Safety Warnings Warnings DANGER! Mortal danger or serious injury from electric shock! Maintenance work on live parts may only be carried out by qualified specialist personnel. Observe the safety distance from voltage-carrying parts at all times. Inhalation of toxic exhaust fumes can cause death or serious health damage! Toxic gases are produced when running a combustion engine.
Page 21
Safety Warnings WARNING! Danger of injury and accidents! Danger of injury and accidents due to malfunctioning or improper used safety devices! Do not override safety and protective devices. Do not manipulate or render safety and protective devices. Check safety and protective devices for proper function. ...
Page 22
Safety Warnings Explosion risk from flammable fuel! When working on fuel systems the fuel may ignite and cause life- threatening injuries. Do no smoke. Keep fuel away from naked flame. If you are handling fuel keep a fire extinguisher to hand. ...
Page 23
Safety Warnings Safety clearance of materials conducting electricity to overhead lines Voltage Safety clearance up to 1 kV 1 m (3 ft) 1 kV - 110 kV 3 m (9 ft) 110 kV - 220 kV 4 m (13 ft) 220 kV - 380 kV 5 m (16 ft) Safety distance for fire fighting operations on low-voltage systems...
Page 24
Safety Warnings Safety distance for fire fighting operations on high-voltage systems (1 kV - 380 kV) Extinguishing agent Safety clearance HD-nozzle with full water jet 10 m (32 ft) Water turret with water spray jet 10 m (32 ft) Water turret with full water jet 30 m (98 ft) 24 / 89...
Page 25
Safety Warnings CAUTION! Danger of injury for the operator due to performing action in wrong order! Individual operating instructions must be done in the prescribed order. Danger of hearing damage from standing near the running engine for long periods! Use hearing protection.
Page 26
Safety Warnings Environmental and health hazard due to lubrication oils! Lubrication, transmission and hydraulic oils can cause permanent water pollution and endanger fauna and flora of all types. Avoid skin contact with hazardous oils. Avoid ground contact with lubrication oils. ...
Page 27
Safety Warnings NOTICE Material damage due to thermal overloading of the portable power generator! It is prohibited to operate the portable power generator with closed roller shutters and hinged steps. If the portable power generator is equipped with an exhaust hose through the compartment, the portable power generator should only be operated in stowed position and with open roller shutters or hinged steps for max.
Product description Power generators Product description Power generators The portable power generator is used primarily as a rescue tool and is therefore optimised for operational safety, performance and weight. Portable power generator RS 14 Super Silent The power generator consists of a petrol internal combustion engine with flanged generator in a carrying pan with switch box and control unit as well as a GFRP housing.
Product description Rosenbauer Body Components Logic Control System (RBC LCS) Rosenbauer Body Components Logic Control System (RBC LCS) 5.4.1 RBC LCS Compact RBC LCS Compact The RBC LCS Compact consists of: • RBC LCS display 3.5“ (left) • RBC LCS Digipot (right) The display shows the operating personnel the main status information.
Technical description LCS operation panel RLS lighting head connection Remote start / stop connection (option) USB charging socket connection (option) MAGCODE charging socket connection (option) Three-phase or supply socket (option) RLS lighting head holder (option) LCS operation panel 6.2.1 Function switches Symbol Name Functional description...
Page 32
Technical description LCS operation panel Symbol Name Functional description The switch activates and deactivates the External refuelling external refuelling. The switch allows you to scroll forward Scroll forward one one screen page. For settings the entry screen page field can be moved to the right or for- wards line by line.
Technical description LCS operation panel 6.2.2 Screen Portable power generator Symbol Name Functional description Propulsion engine The indicator shows the current fuel tank fuel tank fill level of the propulsion engine. The display shows the current load on the Generator load generator.
Page 34
Technical description LCS operation panel Symbol Name Functional description The indicator shows the date of the next Service interval service. date The indicator shows the current software version. Software version The display shows the possibility of an in- sulation fault test. ISO TEST Insulation fault test The insulation fault test can only be car-...
Page 35
Technical description LCS operation panel Pilot lamps Symbol Name Functional description The control shows the condition of the speed reduction. The pilot lamp has three switching condi- ECO mode tions: (optional) • Grey: preselected • Green: active, speed lowered • Black: deactivated The control indicates a possible over- heating of the power generator.
Technical description Optional equipment Optional equipment 6.3.1 Exhaust gas hose DANGER! Inhalation of toxic exhaust fumes can cause death or serious health damage! Toxic gases are produced when running a combustion engine. Operation in the immediate vicinity of flammable material and substances is prohibited. In order to properly discharge hot exhaust gases, use the provided, standardised exhaust hose.
Technical description Optional equipment Holder for exhaust gas hose 6.3.3 45° exhaust adapter The exhaust adapter serves for lateral deflection of the exhaust gas. Through its use the exhaust gases are laterally deflected from the side of the power generator. 45°...
Technical description Optional equipment 6.3.5 Wheel set with pulling device Assembly of the wheel set may only be carried out by trained specialist per- sonnel. Take note of general dangers that could occur during assembly. The power generator can be equipped with a wheel set and a pulling device for manoeuvring and 1-man transport.
Technical description Optional equipment Locking bolts 6.3.6 Trolley For transportation, the power generator can be equipped with a trolley. In order to manoeuvre the trolley well, it is equipped with two steerable and brakeable transport castors. In order to manoeuvre the trolley well, it is equipped with four transport cas- tors (2 pcs.
Technical description Optional equipment Filler neck The filler neck, which is an attachment for the fuel canister, must always be used when refuelling. Filler neck 6.3.8 External refuelling set A 1.5 m connection line between the fuel canister and the external fuelling connector (7)on the power generator.
Technical description Optional equipment For further information, please refer to the manufacturer's operation manu- 6.3.10 Socket distributor Mobile plastic distributor 2 x 400 V,IP 44. With 3 metre cable HO7RN-F 5G 1.5 mm². Input socket 16 A, 5 p, 400 V. 2 CEE 16 A, 400 V sockets. 400 V socket distributor 6.3.11 Tool kit...
Page 42
Technical description Optional equipment Assembly of the adapter may only be carried out by trained personnel. Take note of general dangers that could occur during assembly. ► Mount tripod adapter and plain bearing to the retaining plate with oval head screws. ►...
The power generator can be started and stopped directly on the power generator independent of the remote monitoring. 6.4.2 Insulation monitoring The RS14 EFI / Super Silent power generator has insulation monitoring. Depending on the variant this is designed as non shut down or shut down . CAUTION! Insulation monitoring If an insulation fault occurs at the power generator or at a consumer ...
Technical description Functional options The insulation monitoring meets the increased need for safety and the cur- rent regulations for mobile power generators installed in vehicles. Mobile power generators with protective separation and insulation monitoring may also be operated by non-electrical specialists. A calibrated earthing system is not required.
Technical description Functional options No error messages are transmitted via the connection cable ► Do not start the generator in enclosed rooms or equipment rooms. ► If the unit is installed in enclosed rooms or equipment rooms, a start interruption must be provided.
Operation Preparation for initial operation Operation Preparation for initial operation The sequence of the described processes is to be maintained without ex- ception! Before initial start-up, check the correct fluid level of all consumables. ► Fuel in tank. ► The power generator is delivered in unfilled state, fill the fuel tank before initial start-up.
Operation Transport 7.2.1 Transporting manually If possible, always carry with 4 people and lift from the knees to reduce the risk of back injuries. Carrying over long distances can lead to excessive strain. 4 people are needed for carrying. ►...
Operation Preparation for startup Dismantle transport device ► The disassembly of the transport device takes place in reverse order to the assembly. The wheels are disassembled. Transporting power generator ► Lift the power generator on the underfloor hydrant key. ►...
Page 49
Operation Positioning the power generator ► Avoid trip hazards caused by cables and fuel lines. Secure laid connection cables, if necessary cover with rubber mats. ► Do not cover the power generator while in operation. ► Ensure the supply of sufficient fresh air. ►...
Operation Monitoring during operation Monitoring during operation All operating elements must always be within reach of the operating per- sonnel. ► During operation, constantly monitor the displays and warnings on the operating elements. ► Continuously monitor critical operating states and fill levels of the op- erating materials.
Page 51
Operation Operation WARNING! Explosion risk from flammable fuel! When working on fuel systems the fuel may ignite and cause life- threatening injuries. Do no smoke. Keep fuel away from naked flame. If you are handling fuel keep a fire extinguisher to hand. ...
Page 52
Operation Operation ► Briefly press the Start power generator function switch to switch on the ignition. The control unit is activated - display illuminates. ► Press the Start power generator function switch to start the power gen- erator. ► Release the function switch immediately after starting.
Operation Operation With the Super Silent design variant the engine hood must be removed before emergency start. ► Release the rubber tensioner on the engine side and remove the hood horizontally. ► Place the power generator on the ground. Force application during the starting process is increased.
Operation Operation ► Press Scroll back screen page or Scroll forward screen pagefunction switch to display the Operating hours screen page. Operating hours screen page appears on the display. Operating hours screen page ► Press the Confirm message function switch for approx. 5 seconds. An ISO error test is performed.
Operation Operation The voltage is regulated by an integrated voltage regulator. The power generator may have different sockets, voltages and fre- quencies for special devices. Connect consumer When using loads equipped with intelligent voltage monitoring devices (e.g. undervoltage detection, direction of rotation detection, frequency monitor- ing, etc.), it must be ensured by the user before start-up that these voltage monitoring devices also comply with the characteristics of a portable power generator (especially with regard to the start-up situation).
Operation Operation ► Briefly press the Stop power generator function switch to shut down the power generator. If the Stop power generator function switch is pressed for 5 sec- onds the display is switched off. If the Stop power generator function switch is pressed for 11 sec- ...
Page 57
Operation Operation NOTICE Engine damage from the wrong fuel! The power generator may only be fuelled with petrol (min. 91 RON), E10 or Aspen four-stroke. Observe pictograms on the power generator. Limited storage life of fuel The fuel in the tank of the power generator must be utilised within six ...
Page 58
Operation Operation ► Open fuel tank cap. The fuel tank cap has a safety fuel cap. Any excess pressure may escape after one eighth turn. ► Fill the tank, but do not overfill! ► Set down the canister and close, then close the tank with the fuel tank cap.
Operation Operation 7.6.6 Functional options ECO mode (speed reduction) The speed reduction depends on the engine temperature and takes place after approx. 20 seconds when the engine is running warm, if no consumers are connected. The engine speed is regulated at a lower speed (2000 rpm). Once consumers are switched on, the motor automatically increases to the nominal speed and the full power is available.
Page 60
Operation Operation Operation for network-independent power supply only for emergency ser- vices. Supply of a public or private network only in compliance with valid laws and standards. Supply only by qualified electrical engineering personnel and in appropriately designed systems. When supplying a public or private network it is necessary to obtain approv- al from the network operator! The switch Direct supply/system supply switches between the direct ...
Page 61
Operation Operation System supply WARNING! Warning of missing protective device! When operating via the system supply, the entire supply line from the power generator via the connecting cable to the feed point in the electrical distributor board is NOT protected by a personal protective device. Only supply according to DIN 14684 ...
Page 62
Operation Operation System supply The power generator is in system supply mode and functions like an earthed TN network. This corresponds to a power supply from a transform- er to a building. The 400 V CEE supply socket (white, 1 o'clock position) is supplied with voltage.
Only technology which is regularly maintained by specialists can meet the high demands. Rosenbauer service partners will gladly provide you with comprehensive advice about inspections and Service PLUS, as well as about the exact scope and costs of testing and maintenance work.
Service and cleaning Maintenance work Maintenance work Maintenance work involves tasks that can be performed by properly trained fire department personnel. This work must be carried out regularly, especially after each use, to ensure optimum condition of the product. ► Keep the safety and warning signs clean and legible.
Service and cleaning Maintenance work ► Clean the device with a suitable sponge or brush. Check the products for contamination before use to avoid surface damage. ► In addition, use a tested car wash detergent to remove road dirt. Do not use household soap or detergent.
Service and cleaning Service plan 8.1.3 Dry vehicle and equipment Load only dried equipment into the vehicle, to conserve the service life of the equipment and the vehicle. ► Let the equipment and device dry before loading. ► Open compartments of the vehicle in the vehicle garage. Service plan 8.2.1 Maintenance according to the manufacturers operation manual...
The generator must be subjected to a recurrent testing in accordance with the relevant national regulations. Observe the applicable laws and regula- tions. Rosenbauer recommends that a recurring test be carried out every 5 years at the latest. The recurring tests are to be documented accordingly.
Service and cleaning Testing and inspection work 8.4.1 Hose lines All hose lines, especially fuel lines, are to be checked at least once a year for obvious defects in the course of a visual check. Note the following criteria when checking hose lines: ►...
Neglecting these recommendations will result in loss of warranty. 8.5.1 Preparatory activities for changing RS14 EFI Super Silent oil filter To change the oil filter on the propulsion engine of the power generator, it is necessary to remove a ventilation plate beforehand.
Mount 2 x fastening screws to each of the lateral top covers with Torx screwdriver. Seal in the fastening screws with a liquid-locking compound, e.g. Loctite. RS14 EFI Super Silent design variant: ► The air filter set is located under the top cover of the power generator.
Service and cleaning Service work Service cover ► Remove the both screws on the service cover. Carefully pull service cover away downwards. Additionally the pump for external refuelling is attached to the ser- vice cover. Do not tension the cable and hoses connected to it. Place a suitable collection vessel underneath the power generator to ...
Service and cleaning Service work • K228 External refuelling (fill level sensor) Diode: • Freewheeling diode starter relay 8.5.5 Fuse strip The fuse strip is located below the battery compartment cover. If an over- load occurs due to a consumer, the circuit breaker is activated. An addition- al message is output on the control unit.
Service and cleaning Service work 8.5.7 Battery WARNING! Danger of serious injury and damage due to chemical burns! Battery acid can cause severe injury to eyes and skin. Follow safety instructions on the outside of the battery. Wear safety goggles whenever servicing a battery. ...
Page 74
Service and cleaning Service work ► Fasten battery and connect battery terminal. In avoid sparks first connect the cable from the plus terminal and then the one from the earth terminal. ► Close battery compartment cover. Starter battery has been replaced. ...
Service and cleaning Service work 8.5.8 General guidelines for handling electronic components NOTICE Neglecting these recommendations will result in loss of warranty. Working on vehicles fitted with electronic devices Installation and measurement of electronic devices. ► Ensure power is switched off before working on electrical parts (except when measuring).
Service and cleaning Preserving and storing Painting work or working with chemicals or aggressive substances: NOTICE Damage to electronic components Due to high temperature in a paint box, electronics can be severely damaged. Expose electronics to max. 95 °C (203 °F) for a short period. ...
Service and cleaning Service menu ► For storage without charge retention the battery is to be disconnected. The leakage current on the electrical components of the power gener- ator is approx. 0.5 mA. To prevent the generation of sparks, the earthing cable of the bat- ...
Service and cleaning Service menu 8.7.2 Set display language Pre-programmed display languages can be set in the service menu. Furthermore, the option No text (xx) can also be set. ► Call up service menu. Refer to chapter "Call up/exit service menu". ...
Page 79
Service and cleaning Service menu General Servcie Stat Month Year 2022 Operating Hour SAVE DATA CFG General service submenu ► Actuate the Confirm message function switch to select the Month set- ting. ► Actuate the Scroll back screen page or Scroll forward screen page function switch to select the desired month.
Failure If problems or repairs can not be clearly identified or solved please contact the customer service department or your Rosenbauer representative. The following list offers an overview of possible faults. The list is not com- plete, but in the event of a malfunction it can be helpful in localising and rec- tifying the fault.
Troubleshooting Warnings Fault Cause Remedy Engine does not start Battery is not connected. Connect battery and check contacts (engine does not Battery empty Charge or replace battery (votmeter) crank) Emergency stop pressed Rotate the switch clockwise, to deactivate the emergency stop No power supply to the con- Check power supply and ground on the trol unit...
Troubleshooting Warnings 9.2.1 RS14 power generator Message Possible cause Corrective action Open power genera- Compartment is closed. Open compartment. tor compartment. Swivel out power Do not operate the power Open compartment. Swivel out power generator! generator in the locker com- generator.
Page 83
Troubleshooting Warnings Message Possible cause Corrective action Insulation error Insulation error test carried Check the insulation of the devices. out. Check the insulation of the power genera- Insulation error occurred. tor. Check generator governor. Check wiring harness insulation. Engine fault! An engine fault has occurred.
Disposal Warnings Disposal Dispose of all materials and old parts that are produced through the han- dling and repair of this unit in an environmentally-friendly way. Disposal of used oil, cooling water and fuels Used oil, cooling water and fuels are water-polluting substances. Ensure the correct disposal of used oils and fuel.
Mobile power generating unit In particular fire departments or users who re- quire a higher level of protection Manufacturer Rosenbauer International AG RS 14 EFI (A0515) Type designation RS 14 EFI SUPER SILENT (A0516) ÖBFV-RL ET-01 / 8 kVA power generator with...
Page 86
Technical data Warnings Generator Number of poles / 2 / 3,000 rpm Speed Distortion factor < 5% Size BG 132 a. country-specific special design: 130 / 225 V b. country-specific special design: 60 V c. +/- 5 % at 130 /225 V d.
Calling up the QR code (QR = Quick Response) provides access to the available documents for the power generator. The online spare parts cata- logue is also available. RS14 power generator (A0515) https://link.rosenbauer.com/fef0bd0d-3047-4e12-8db2-a20c84a33a37 RS 14 SuperSilent power generator (A0516) https://link.rosenbauer.com/15ce45cb-a4d4-4b9e-9a4b-f8f26de739a9 87 / 89...
Index of abbreviations Index of abbreviations Fire fighting abbreviations Power takeoff Normal pressure High pressure AFFF Aqueous film forming foam compound O-stream nozzle UHPS Ultra High Pressure System CAFS Compressed Air Foam System General abbreviations i.n. if necessary e. g. for example approx.
Page 89
Index of abbreviations Abbreviations for units gallons Pressure unit Pounds per square inch Volt DC voltage Ampere Kilo volt-ampere Watts Kilowatts Hertz Kilonewtons Centistokes Diameter nominal Decibel °C Degrees Celsius °F Degrees Fahrenheit l/min Litres per minute Gallons per minute kg/s Kilogram per second lbs/s...
Need help?
Do you have a question about the RS14 EFI and is the answer not in the manual?
Questions and answers