Synthesizer Troubleshooting; Incorrect Pll Frequencies - Nokia RH-66 Troubleshooting Manual

Rf description and troubleshooting
Hide thumbs Also See for RH-66:
Table of Contents

Advertisement

2115i/2116/2116i (RH-66)
RF Description and Troubleshooting

Synthesizer Troubleshooting

Faulty synthesizers can cause both Rx and Tx failures during tuning, in addition to the
VCTCXO tuning. However, first check for the presence of various LO signals and their
proper levels. The 19.2 MHz reference clock is needed for the mobile terminal to power
up. Therefore, if everything fails, check for the presence of 19.2 MHz. The level of
19.2 MHz is also important because the UPP is very sensitive and can still pick up a very
weak 19.2 MHz clock, which can result in the mobile terminal constantly resetting. See
"19.2 MHZ VCTCXO Reference
The following synthesizers are used:
• Dual-band UHF with separate PLL IC and VCO
1009.62 MHz for channel 384 in Cell/AMPS
2088.1 MHz for channel 600 in PCS
• Tx UHF with PLL inside N7000 IC
3296.16 ~ 3395.88 MHz for Cell and AMPS
3700 ~ 3819.9 MHz for PCS
• Rx VHF with PLL inside N7100 IC
256.2 MHz for Cell, AMPS, and PCS

Incorrect PLL Frequencies

Following are possible causes for incorrect PLL frequencies:
• Incorrect power supplies to the PLL portion
• Control line to the VCO
• Loop filter or resonator components missing or incorrectly installed
• 19.2 MHz reference clock is missing or low
• Component failure (PLL IC, N7100, N7000, VCO, or VCTCXO)
Page 28
Clock" on page
©2005 Nokia Corporation
30
for more information.
Company Confidential
Issue 1 03/2005