Testing The Cdma Antenna; Calibration Factors; Calibration Factor For Pcs1900 Frequency; Measurement Procedure - Nokia RH-66 Troubleshooting Manual

Antenna description and troubleshooting
Hide thumbs Also See for RH-66:
Table of Contents

Advertisement

2115i/2116/2116i (RH-66)
Antenna Description and Troubleshooting

Testing the CDMA Antenna

Calibration Factors

Use the MJF-28 Docking Station Adapter to define the CPL-8 Antenna Coupler
calibration numbers. Obtain the calibration numbers by utilizing a mobile terminal with
known RF and antenna performance. Each test adapter should only require a single
calibration on PCS1900 and GPS bands at used test frequencies. Additional calibrations
should only be needed if the test adapter is substantially modified (reassembled, changed
parts, dropped, etc.).

Calibration Factor for PCS1900 Frequency

Use a call box to turn on the mobile terminal's transmitter with a known output power
and antenna performance at the maximum output power (all bits up). Measure the
transmitted power on the RF connector and through a coupler at CDMA PCS channel
1175. Use the difference between the transmitted and received powers as the calibration
number (path loss on Cell band including coupler, cable, and attenuator path losses) for
the coupler on Cell band.
The nominal value for power measured at the RF connector is 23 dBm. The coupler path
loss is normally from 17 to 18 dB at the PCS band. If you use a 10 dB attenuator and a
cable with ~1 dB loss, the total path loss is from 28 to 29 dB and the measured power
should be from -5 to -6 dBm [23 dBm - (28...29 dB)]. However, you must measure path
loss separately for every coupler because path losses vary depending on the setup, cables,
and attenuator.

Measurement Procedure

Use the following measurement procedures for 800/1900 mobile terminals:
1. Place the mobile terminal in the MJF-28 Docking Station Adapter with the
display facing upward and its whip retracted.
2. Turn on the mobile terminal's transmitter at the PCS band on CDMA mode
channel 1175 at maximum output power (nominal 23 dBm at RF connector).
3. Measure the RF power with a CPL-8 Antenna Coupler. This represents the internal
antenna to RF coupler measurement.
4. Turn the mobile terminal's transmitter off.
The CDMA antenna test fails if the measured power is outside the test limits.
Min Measured Power + Coupler,
Cable and Attenuator Path Loss
20,0 dBm
Page 10
Table 1: CDMA Measurement Test Limits
Nominal
23 dBm
©2005 Nokia Corporation
Max Measured Power + Coupler,
Cable and Attenuator Path Loss
26,0 dBm
Company Confidential
Issue 1 03/2005

Advertisement

Table of Contents
loading

This manual is also suitable for:

2115i21162116i

Table of Contents