Download Print this page

Orientalmotor K Series Quick Start Manual

Terminal box type induction motors and reversible motors

Advertisement

Quick Links

OPERATING MANUAL
World K Series
Induction Motors and Reversible Motors
Before using the motor
■ Introduction
Only qualified personnel should work with the product. Use the product
correctly after thoroughly reading the section "Safety precautions".
Should you require the inspection or repair of internal parts, contact the
Oriental Motor office where you purchased the product.
The product described in this manual has been designed and manufactured
for use in general industrial machinery, and must not be used for any other
purpose. Oriental Motor Co., Ltd. is not responsible for any damage caused
through failure to observe this warning.
■ Standard and CE marking
Motors are recognized by UL and certified by VDE or DEMKO.
Recognized name and certified name are motor model name.
Voluntary display of the CE mark conforming to the Low Voltage Directives.
z Standards
UL 1004-1, UL 1004-2, UL 1004-3
CSA C22.2 No.100, CSA C22.2 No.77, EN 60950-1 or EN 62368-1
Standards File No.
UL File No. E64199 (6 W type), E64197 (60 to 90 W type), VDE, DEMKO
z Applications for standard
EN 60034-1, EN 60034-5, EN 60664-1, EN 60950-1 or EN 62368-1
Temperature rise tests required by the standards are conducted for the round
shaft type motors are conducted in a state of attaching a heat radiation plate.
The size, thickness and material of the heat radiation plates are as follows.
First number in
Size [mm (in.)]
motor name
2
115 × 115 (4.53 × 4.53)
5
200 × 200 (7.87 × 7.87)
z Installation conditions
Overvoltage category
, Pollution degree 2, Class
When the machinery to which the motor is mounted requires overvoltage
category
and pollution degree 3 specifications, install the motor in a cabinet
that comply with IP54 and connect to power supply via an isolation transformer.
z Standards for accessories
Capacitor : UL File No. E83671 (CYWT2),
VDE Licence No.112847 (for only capacitor rated voltage 250VAC types,
capacitor model ending in FAUL2),
VDE License No. 114747 (for capacitor rated voltage 450 VAC types)
Capacitor cap : UL File No. E56078 (YDTU2)
Safety precautions
The precautions described below are intended to prevent danger or injury to
the user and other personnel through safe, correct use of the product. Use the
product only after carefully reading and fully understanding these instructions.
Handling the product without observing the
WARNING
instructions that accompany a "WARNING" symbol
may result in serious injury or death.
Handling the product without observing the
CAUTION
instructions that accompany a "CAUTION" symbol
may result in injury or property damage.
The items under this heading contain important
Note
handling instructions that the user should observe
to ensure safe use of the product.
• Do not use the product in explosive or corrosive environments, in the
presence of flammable gases, locations subjected to splashing water, or near
combustibles. Doing so may result in fire, electric shock or injury.
HM-9189-6
Terminal Box Type
Thickness
[mm (in.)]
5 (0.20)
equipment (For EN standards)
WARNING
Thank you for purchasing an Oriental Motor product.
This Operating Manual describes product handling procedures and safety
precautions.
• Please read it thoroughly to ensure safe operation.
• Always keep the manual where it is readily available.
• Assign qualified personnel the task of installing, wiring, operating/ controlling,
inspecting and troubleshooting the product. Failure to do so may result in
fire, electric shock or injury.
• Do not transport, install the product, perform connections or inspections
when the power is on. Always turn the power off before carrying out these
operations. Failure to do so may result in electric shock.
• Turn off the power in the event the overheat protection device (thermal
protector) is triggered. Failure to do so may result in injury or damage to
equipment, since the motor will start abruptly when the overheat protection
device (thermal protector) is automatically reset.
• The motor is Class
hands, or ground it to prevent the risk of electric shock. If the motor has a
protective ground terminal, be sure to connect the terminal to the ground.
Dieser Motor ist in Geräten mit Schutzklasse I zu verwenden. Der Motor ist
so einzusetzen, dass er nicht berührt werden kann, bzw. er ist zu erden, um
Stromschläge zu verhindern. Wenn der Motor über eine Schutzerdungsklemme
verfügt, ist die Erdung über diese vorzunehmen.
• Install the motor in an enclosures in order to prevent electric shock or injury.
• Keep the input-power voltage within the specification to avoid fire and
electric shock.
• Connect the cables securely according to the wiring diagram in order to
prevent fire and electric shock.
• Do not forcibly bend, pull or pinch the lead wires. Doing so may result in fire
and electric shock.
• Be sure to insulate the connection terminal of the capacitor. Failure to do so
may result in electric shock.
• Turn off the power in the event of a power failure, or the motor will suddenly
start when the power is restored and may cause injury or damage to equipment.
• Do not touch the connection terminal of the capacitor immediately after the
power is turned off (for a period of 30 seconds). The residual voltage may
Material
cause electric shock.
• Do not disassemble or modify the motor. This may cause electric shock or injury.
Aluminium
• Do not use the motor beyond its specifications, or electric shock, injury or
damage to equipment may result.
• Do not touch the motor during operation or immediately after stopping. The
surface is hot and may cause a burn.
• Do not hold the motor output shaft. This may cause injury.
• Keep the area around the motor free of combustible materials in order to
prevent fire or a burn.
• To prevent the risk of damage to equipment, leave nothing around the motor
that would obstruct ventilation.
• To prevent bodily injury, do not touch the rotating parts (output shaft, cooling
fan) of the motor during operation.
• When an abnormality is noted, turn off the power immediately, or fire, electric
shock or injury may occur.
• The motor's surface temperature may exceed 70 °C, even
under normal operating conditions. If a motor is accessible
during operation, post the warning label shown in the figure
in a conspicuous position to prevent the risk of burns.
• Dispose the product correctly in accordance with laws and regulations, or
instructions of local governments.
Preparation
■ Checking the product
Upon opening the package, verify that the items listed below are included.
Report any missing or damaged items to the branch or sales office from which
you purchased the product.
• Motor ..................................................................1 unit
• Capacitor ...........................................................1 piece (only for single-phase motor)
• Capacitor cap ...................................................1 piece (only for single-phase motor)
• Operating manual (this manual) ..............1 copy
equipment. Install the motor so as to avoid contact with
CAUTION
Warning label
1

Advertisement

loading

Summary of Contents for Orientalmotor K Series

  • Page 1 HM-9189-6 OPERATING MANUAL Thank you for purchasing an Oriental Motor product. World K Series Terminal Box Type This Operating Manual describes product handling procedures and safety precautions. Induction Motors and Reversible Motors • Please read it thoroughly to ensure safe operation.
  • Page 2 ■ Checking the model name Note Do not insert the motor into the mounting hole at an angle or force it in, as Check the model number against the number indicated on the product. this may scratch the flange pilot section and damage the motor. z Induction motors Model Motor model...
  • Page 3 ■ Wiring diagram • Also refer to the tightening torque table to determine the appropriate tightening torque to use when fastening the terminal box cover and terminal Connect the motor according to the figure. block. Directions of rotation in the diagram are shown as viewed from the flange Terminal box cover 0.3 N·m (42 oz-in.) surface of the motor.
  • Page 4 5:00 , P.S.T. (M-F) Tel:1800-8420280 A.M. P.M. When the motor goes into locked rotor condition due to a malfunction, coil www.orientalmotor.com.sg 7:30 to 5:00 , C.S.T. (M-F) A.M. P.M. impedance rises, suppressing input power to the motor and protecting the www.orientalmotor.com...

This manual is also suitable for:

2ik6gn-awtj2ik6gn-awtu2ik6gn-cwtj2ik6gn-cwte5ik60gu-awtj5ik60gu-awtu ... Show all