Download Print this page

DCS RD 484 GG Part List / Service Manual page 16

Advertisement

LEAK / OPEN TOP TROUBLESHOOTING
P RO B L E M A R E A :
Customer smells gas at
all times
Customer smells gas
only when Open Top
Burners, Large Oven,
or Grill are in opera-
tion
Open Top Burner
Doesn't Light
W H A T T O D O :
CHECK for LEAKS at:
A) The two brass elbows coming from the
1/2"NPT pipe between the regulator and manifold
B) Along the manifold at every nut/washer
point and plug
C) At all connection points between tubing
and thermal valves at grill and griddle locations.
CHECK for LEAKS at:
A) The Thermal Valve and connections sup-
plying the Grill, with Grill turned on.
B) O-Ring between the Simmer Block and
Simmer Valve for all Open Top Burners, with burn-
ers on.
Is the igniter sparking? The spark should be
jumping to the simmer burner cap.
A) Make sure that the lead to the electrode is
secure, as well as the lead to the Spark Module and
that there is power also.
B) Spark Switches at control knobs should be
checked for power to and coming out from (with
knob in "lite" position. If there is power going to, yet
not coming out the other side, replace spark switch.
C) See Open Top Burner Lighting and
"Adjustable Low Setting" sections in the Installation
Manual.
15
U S E F U L N OT E S :
NOTE: If using a
soap and water solution
when checking for
leaks, be careful not to
get any water on Spark
Switches, as doing so
will cause a short in the
switch.
NOTE: It is important
that correct # wire be
traced from the Spark
Switch,to the Spark
Module, to the Burner
Electrode.

Advertisement

loading