Fujitsu UTW-SCBYA Installation And Operating Manual page 21

Table of Contents

Advertisement

Line
Function
923
S
Flow temp setp min OT 25°C
The lowest starting temperature for cooling for an outdoor temperature of 25 °C.
924
S
Flow temp setp min OT 35°C
The lowest starting temperature for cooling for an outdoor temperature of 35°C.
Flow temperature setpoint
°C
908
20
923
18
924
909
Flow temperature setpoint
16
(without minimum limit)
928
S
Room influence
If the installation is fitted with an room sensor :
This function enables you to choose the ambient temperature's influence on the setting.
If no value is entered, the setting is made based on the temperature control.
If the parameter is set at 100%, the setting is only based on the ambient temperature.
932
S
Room temp limitation
938
S
Mixing valve decrease
941
S
Actuator running time
945
S
Mixing valve in heating mode
946
S
Lock time dewpoint limiter
947
S
Flow temp setp incr hygro
948
S
Flow setp incr start at r.h.
950
S
Flow temp diff dewpoint
963
S
With prim contr / system pump
969
S
Operating mode changeover
figure 19 - Water start temperature limit
Geographical area

Internal area
Coastal area (width 30 km)
Coastal area (width 50 km)
Coastal area (width 50 km)
Coastal area (width 50 km)
The water temperature must be restricted to a value set according to the geographical area. Setting to the lowest temperatures
runs the risk of causing condensation on the floor, together with all the other risks this may engender.
If the limit temperatures are not observed, the manufacturer may not be held responsible for any physical injuries or damage
to equipment that may be caused.
Installation and operating manual "1395 - EN"
Flow temperature setpoint
(with minimum limit)
30
25
Outside temperature
Water start
temperature limit
(line 923 & 924)
18°C
19°C
20°C
21°C
22°C
Setting range or display
6... 35 °C
6... 35 °C
figure 18 - Limitations on the
startingtemperature setting
°C
35
--, 1... 100 %
--, 0,5... 4 °C
0... 20 °C
30... 873 s
Control, Open
--, 10... 600 min
--, 1... 20 °C
0... 100 %
--, 0... 5 °C
No, Yes
No, Off, Automatic
2
3
4
Control Box
Setting
Basic setting
increment
0,5 °C
18 °C
0,5 °C
18 °C
1 %
80 %
0,5 °C
0,5 °C
1 °C
0 °C
1 s
240 s
Control
10 min
60 min
1 °C
10 °C
1 %
60 %
1 °C
2 °C
No
Off
1
5
- 21 -