8.2 SILENT OPERATION (Outdoor Unit)
Keep outdoor unit operating silently to ensure either yourself or neighborhood
will have a tight sleep in nighttime. By this feature, the cooling capacity will
be optimized to deliver such silent experience. The silent operation can be
selected from one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 > Silent 2
Silent 1:
● Though operating silently, the Cooling capacity is still prioritized to ensure
having sufficient comfort inside the room.
● This setting is a perfect balance between the Cooling capacity and the
Sound level of outdoor unit.
Silent 2:
● Compromising the Cooling capacity to the Sound level in any circumstance
where the outdoor unit's sound level is highly prioritized.
● This setting has a purpose to reduce the maximum sound level of outdoor
unit.
Note:
● While activating of Silent operation, inadequate cooling capacity may occur.
Silent Operation Setting
1. Press MENU button for enter menu selection
MENU
MEN
During triangle mark blink
2. Enter SILENT set by press MENU button.
triangle mark will stop blink and setting feature will be blink instead.
MENU
MEN
3. Select SILENT operation by press TEMP. button.
SILENT#1
SILENT#2
4. Confi rm selected feature by press MENU button again.
MEN
MENU
When feature had selected will return to menu selection display triangle mark
will blink
5. Leave from menu setting display by select EXIT.
MEN
MENU
Blink
°C
can select menu by press TEMP. button.
Blink both triangle and
feature mark Feature not
°C
yet set
°C
°C
None
Blink only triangle
Feature already set
°C
°C
8.3 Hi POWER OPERATION
To automatically control room temperature and airfl ow for faster cooling
operation (except in DRY and FAN ONLY mode)
1. Press MENU button for enter menu setting and press TEMP. button to
select Hi POWER
MEN
MENU
2. Confi rm selected feature by press MENU button again.
MEN
MENU
3. Leave from menu setting display by select EXIT.
8.4 ECO OPERATION
To automatically control room temperature to save energy
(except in DRY and FAN ONLY mode)
1. Press MENU button for enter menu setting and press TEMP. button to
select ECO
MEN
MENU
2. Confi rm selected feature by press MENU button again.
MEN
MENU
3. Leave from menu setting display by select EXIT.
MEN
MENU
Note:
● Cooling operation; the set temperture will increase automatically
1 degree/hour for 2 hours (maximum 2 degrees increase).
Blink both triangle and
feature mark Feature not
°C
yet set
Blink only triangle Feature
already set
°C
°C
ECO
Blink both triangle and
feature mark Feature not
°C
yet set
Blink only triangle Feature
already set
°C
°C
Hi-P