This page was intentionally left blank BOH-PM-13-2 Chapter 2 Rev. 0.01...
Page 3
0007 00 OPERATOR INSTRUCTIONS ® SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units PREPARATION FOR MOVEMENT AND TRANSPORT Prior to moving the office module either by forklift or within a container, all internal and external components must be properly secured.
Page 4
0007 00 Positioning Office Module from the transport to the site Office Module GROUND GUIDE GROUND GUIDE DIRECT LINE OF SIGHT DIRECT LINE OF SIGHT WARNING Ground guides and the HME operators must maintain direct line of sight and insure that personnel are clear of the office module during this operation. Overhead power lines and obstructions can cause serious injury or damage to property.
Page 5
0007 00 Office modules may be secured within the FPU-8-2 and FPU-20-1 and 20-2 by means of the fixed floor cradles and module locking arms (2). They may also be secured within the FPU-8-4 and FPU-20-3 by first inserting removable cradles to the floor of the containers in order to provide the foot pads (1) and locking arms (2).
Page 6
0007 00 Setup and Preparation When used outside an FPU container, the Office Module must be placed on a level site to stabilize the module and permit a level working environment. 1. Inspect the site and remove rocks roots and debris that would prevent the module from being placed on a firm level site.
Page 7
0008 00 OPERATOR INSTRUCTIONS ® SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units OPERATION OF OFFICE MODULE ENTRANCE DOOR OPERATION The office module entrance door consists of an upper and lower door section which swing and lock independent of each other to allow for the raising and lowering of the roof section.
Page 8
0008 00 Lower Door The lower door is the larger door of the two and includes a two-point lock system and separate set of keys (1). The top lock can be unlocked from the inside simply be pulling the handle. The bottom lock acts as a deadbolt lock (2) and can be locked from the inside by twisting the red thumb lever clockwise.
Page 9
0009 00 OPERATOR INSTRUCTIONS ® SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units OFFICE MODULE ROOF HEIGHT CONFIGURATIONS The BOH Office Module provides the unique capability of raising and lowering the roof of the module to various heights depending on whether the module is to be housed inside an FPU container, stand-alone outside the container or per the preference of the user.
Page 10
0009 00 2. The 2 position (2) can be used within an FPU-8 or FPU-20 series container should the customer desire this height. *Internal Ceiling Height = 70” 3. The 3 position (3) can be used within an FPU-20 series container should the customer desire this height.
Page 11
0009 00 ROOF HEIGHT ADJUSTMENT The BOH Office Module provides a jack assembly and roof elevating lock assemblies to safely and properly lift the module roof to the desired height once the module has been transported to its deployed location. Jack Assembly Storage The office module provides designated storage locations for the jack assembly within the module.
Page 12
0009 00 The jack device and main subassembly (1) is secured within the office module against the wall opposite the desk by two wall brackets (2). These brackets include a spring-loaded knob (3) that secure to the main subassembly by locking into two designated holes (4) in the side of the subassembly. The subassembly can be removed from these brackets by a simple pull and twist of the knobs until they lock in the out position (5).
Page 13
0009 00 Procedure for Raising the Roof WARNING The Pop-up roof component of the office module is held in place and positioned by the 3 roof elevating lock assemblies found inside the container. While it is possible for the roof to be separated from the main bottom component of the office module, it is not recommended this be performed by anyone other than the manufacturer.
Page 14
0009 00 5. Insert the base assembly pins and lock. 6. Once all jack assembly components are secured, begin operation of the jack. To properly operate the jack, first move the bottom lever (1) to the up position. Then begin cranking the jack handle (2) in a downward motion.
Page 15
0009 00 CAUTION Under no circumstances shall the roof be extended past the 4 hole position. Failure to comply may cause damage to the roof elevating lock assembly and may make the roof and jack unstable. Any maintenance requiring the removal of the roof shall be coordinated directly with the manufacturer. 15.
Page 16
0009 00 Procedure for Lowering the Roof 1. Repeat steps 1 through 8 from the Raising procedure to secure the completed jack assembly against the office module ceiling. 2. Pull and twist the spring-loaded knobs from the front of the roof elevating lock assemblies until the knobs are locked in the out position.
0010 00 OPERATOR INSTRUCTIONS ® SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units ELECTRICAL SYSTEM Electrical and Communications Connections The Office Module is provided with a communication connection box (1), a 120V outlet (2) with protective weather cover and connection cable (3), cable pass-through (4) and external ground lug (5).
Page 18
0010 00 Establishing Power Supply The Office Module supplies an electric adapter cord and 30A 120V outlet to connect to electrical supply source. 1. Before any electrical connections are made, enter the Office Module and ensure the main circuit breaker and all the circuit breakers are turned off. Also ensure the main power source has been turned off.
Page 20
0010 00 Establishing Communication Lines The Office Module supplies 4 sources of communication lines: dual Cat-3 (telephone) (1), Cat-5 (internet) (2), coaxial cable (3) and dual WF-16 field cable (4). The internal connection side of the communication box is pre-run for Cat-3 and Cat-5 through raceways (5) to designated user connection plugs. Dual Cat-5 plugs (6) are located above the upper shelf, and dual Cat-3 plugs are located below the desk adjacent to a dual electric outlet.
Page 21
0010 00 Office Module Lighting Systems The Office Module is internally lit by two sets of light fixtures (1), each with a fluorescent white and red bulb. NOTE The curled electric cord (2) connected between the light switch (3) and lighting interrupter switch (4) mounted above the door powers the lights.
Page 22
0010 00 Activated Red Lighting OFFICE MODULE HVAC SYSTEM The Office Module comes equipped with an 8,000 BTU HVAC unit located at the rear of the module above the desktop. Refer to Operating Instructions and General Specs found in the Appendix for product details.
Page 23
0010 00 Should the unit be difficult to push into the extended position, it may be necessary to push the unit in evenly from the outside first. This will help better align the unit when attempting to push out. 3. Once the unit is fully extended, attach the velcro covers (1) together with the top cover overlapping the two side covers.
Page 24
0010 00 HVAC Preparation for Transport 1. First, remove all obstructions in front of the HVAC unit inside the office module and unplug the unit. 2. Detach the velcro covers outside the module to expose the HVAC left and right slides. 3.
Page 25
0011 00 OPERATOR INSTRUCTIONS ® SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units OPERATION OF INTERNAL COMPONENTS The internal components provided within the office module are designed for 2-person office use. These components include a general storage cabinet, 2-drawer file cabinet, desktop, 2 chairs, upper shelf with ratchet straps, HVAC system, jack assembly and electrical and communication hookups.
Page 26
0011 00 Upper Shelf Ratchet Strap Operation To release the ratchet straps, pull the release bar as shown. WARNING You must check all straps for proper threading and tension. Refer to these following instructions for each strap. Failure to do so may cause equipment damage or injury. CAUTION Do not operate the ratchet handle (1) until all the slack is taken up by hand or the strap will ball up and jam against the release lever.
Page 27
0011 00 Storage Cabinet The storage cabinet (5) is a general storage space located across from the file cabinet in the rear right corner of the office module. The cabinet door is opened by pulling the ring latch (6) on the front of the door. The ring latch will click back into place once the door is securely closed.
Page 28
This page was intentionally left blank BOH-PM-13-2 Chapter 2 Rev. 0.01...
0012 00 OPERATOR INSTRUCTIONS ® SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack-up Units OPERATION UNDER UNUSUAL CONDITIONS INITIAL SETUP: Office Module Downloaded, Storage and Setup Maintenance Level Personnel Required Operator/Crew Two (plus one supervisor) OPERATION UNDER UNUSUAL CONDITIONS This work package provides instructions for the operation of the Office Module under unusual conditions.
Page 30
0012 00 Interim Nuclear, Biological, and Chemical (NBC) Decontamination Procedures WARNING The Office Module is NOT designed to be operated in contaminated NBC Environments. Do not operate the module in contaminated NBC environments. If possible, cease operation of the Office Module prior to an NBC event and close all doors.