Device for ultrasonic aerosol therapy with a very refined design and new technology, characterized by
extreme noiselessness. With the traditional ultrasonic aerosol devices, compounds for inhalation are
transformed, by means of oscillation of a piezoelectric crystal embedded in the device, into liquid
micro-drops dispersed in air. In this aerosol therapy device, this transformation occurs by means of
the flow of the drug in the micro-holes of a foil.
The microdroplets of the drug, ranging in size between 1 and 5 um, are able to penetrate deep into
the upper and lower respiratory tract, targeting the active ingredients where needed.
Aerosol therapy is effective for the treatment of lung disorders, tracheitis, asthma, bronchitis, sinusitis
and allergies. It can also instantly relieve symptoms caused by colds and allergic irritations, decreasing
the urge to cough, and alleviating sinus pain and pressure, facilitating expectoration. It is an excellent
device for home use, is practical and easy to use.
It is built in compliance with current European standards regarding general requirements for the safety
of medical electrical equipment (Standard EN 60601-1).
The product's small size makes it extremely convenient for those who must use it several times a day
and for those who travel.
The use of oil-based drugs or those with solid elements as active ingredients (suspensions), viscous
solutions or essential oils, is not recommended.
Always follow the doctor's instructions for the type of medicine to use, the dosage,
frequency and duration of inhalations.
Laica S.p.A. - Viale del Lavoro, 10 – Fraz. Ponte
36021 Barbarano Vicentino (VI) - Italy
Made in China
BEFORE USE IT IS IMPORTANT TO READ THE INSTRUCTIONS AND WARNINGS
CONTAINED IN THIS BOOKLET CAREFULLY AND KEEP IT IN A SAFE PLACE FOR FUTURE
REFERENCE.
GENERAL WARNINGS
Using any electrical appliance entails compliance with a number of fundamental rules:
• Unplug the appliance from the mains straight after use and before commencing cleaning or inserting/
removing accessories.
• Do not unplug by tugging on either power cord or appliance.
• If an electrical appliance falls into the water, do not attempt to retrieve it; instead, unplug immediately.
• Do not use the appliance while bathing or showering.
• Never immerse the appliance in water or other liquids.
• Never leave the machine running unattended. Do not allow the appliance to be used
by children, invalids or disabled individuals without adult supervision.
• This appliance must be used solely for the purpose for which it was designed and in accordance
with the operating instructions. Any other use shall be considered improper and hence hazardous.
The manufacturer cannot be held responsible for any damage resulting from improper or incorrect
use.
• Keep all parts of the packaging away from children (choking hazard).
• Before using the appliance, make sure it is intact and does not feature any visible signs of damage.
If in any doubt, do not use the appliance and contact your dealer.
• In the event of a fault and/or irregular operation, turn the appliance off at once without tampering
DEVICE FOR ULTRASONIC AEROSOL THERAPY
with it. Always contact your dealer for repairs.
• Keep the appliance away from sources of heat.
• Make sure your hands are dry when unplugging or plugging in the appliance and when turning
the function control knob.
• This device shall be used only with the voltage stated in this booklet.
• Device with enclosure not protected against the penetration of liquids.
• Do not use the device close to high-frequency electromagnetic emitters.
• Do not use the appliance in the presence of flammable gases and in very dusty areas.
• Do not use the device, if in the nebulization chamber there is not liquid or if the
liquid is present in limited quantities.
• Do not use powder medicinal products, powder medicinal products associated to liquid ones, or
acid medicinal products with this appliance. Do not atomise water. Always use saline.
• Always clean the appliance after each use in order not to let the residual medicinal
products solidify and damage the mechanism.
• During inhalation, keep the unit away from the eyes because some medicines can irritate and / or
burn eyes.
• The device must only be used with the original accessories indicated in the instruction manual.
• Power outages, unexpected problems or other unfavourable conditions can make the device
unusable. Therefore, we recommend keeping a spare device or substitute medicine (as agreed
upon with the doctor).
• Do not use the device in a room where a spray was previously used. If you still wish to use the
unit, we recommend airing the room before starting treatment.

IMPORTANT WARNINGS

• In case of diabetes or other illnesses, it is suggested to consult your physician before undergoing
the inhalation therapy.
• Pregnant women should consult their physician before undergoing the inhalation therapy.
• Before using a preparation, clear with your physician, if it is suitable for the person to use it. Use
only medicines prescribed or suggested by your physician.
• To dilute the preparation, use exclusively an isotonic solution of sodium chloride, since otherwise
respiratory problem may arise.

ACCESSORIES / COMPONENTS

1)
On/Off Button
2)
Operating (On/Off) and low battery light
3)
Atomisation chamber cover
4)
Atomisation chamber
5)
Atomisation dispenser
6)
Atomisation chamber fastener
7)
Mouthpiece
8)
Adult mask
9)
Child mask
10) Mask attachment
11) Battery compartment
12) Mains outlet