Advertisement

Quick Links

AP2000
Operation & Maintenance
Manual
©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com
O&M_AP2000_10084_20210519

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AP2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IXOM AP2000

  • Page 1 AP2000 Operation & Maintenance Manual ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com O&M_AP2000_10084_20210519...
  • Page 2: Table Of Contents

    Table of Contents AP2000 Operation & Maintenance Manual Safety Package Contents Installation Operation Deployment Maintenance Technical Data Sheet Warranty Customer Service ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10014_20210413 O&M_AP2000_10084_20210519...
  • Page 3: Safety

    Most accidents can be avoided by using common sense and concentration on the job being done. Carefully read safety information when you see any safety symbols. ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 1949_10036_20210428 O&M_AP2000_10084_20210519 - 1...
  • Page 4 CAUTION: EDGES MAY BE SHARP AND CAUSE WARNING: ICE SURROUNDING MACHINE MAY LACERATION IF PROPER CARE IS NOT USED. NOT SUPPORT WEIGHT, KEEP CLEAR OF THIN ICE. ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 1949_10036_20210428 O&M_AP2000_10084_20210519 - 2...
  • Page 5 "OFF" position. The On/Off switch is to be their own safety and health programs approved by OSHA. used as the emergency stop. ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 1949_10036_20210428 O&M_AP2000_10084_20210519 - 3...
  • Page 6: Package Contents

    *AU-200 100’ Air Hose * For application where the water depth is deeper than 12’, contact Ixom Watercare Customer Service at 1-866-437-8076 for free change out to deep water compressor. ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10085_20210503 O&M_AP2000_10084_20210519 - 4...
  • Page 7 *AU-200 100’ Air Hose * For application where the water depth is deeper than 12’, contact Ixom Watercare Customer Service at 1-866-437-8076 for free change out to deep water compressor. ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10085_20210503 O&M_AP2000_10084_20210519 - 5...
  • Page 8: Installation

    ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10086_20210430 O&M_AP2000_10084_20210519 - 6...
  • Page 9 ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10086_20210430 O&M_AP2000_10084_20210519 - 7...
  • Page 10: Operation

    AP Unit to run on a timer or local SCADA system. Refer to air supply manufacturer for recommended duty cycle and other operational recommendations and constraints. ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10087_20210430 O&M_AP2000_10084_20210519 - 8...
  • Page 11: Deployment

    To set intake depth, the anchor chain should be 30” less than desired intake measurement. Figure 1: Typical Deployment (Not to scale) Air unit should be located away from water. Model May Vary. ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10221_20210519 O&M_AP2000_10084_20210519 - 9...
  • Page 12 Part Number Size Hose Barb, Male Cam Lock 100679 3/4” 100680 1” 100681 1 1/2” Subject to change without notice. Hose Splice Connection ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10221_20210519 O&M_AP2000_10084_20210519 - 10...
  • Page 13 Quick Coupling, Female Cam Lock *Part Not included in kit, use part from Air Supply Hardware Kit Parts. Optional Optional Configuration Configuration Tee Fitting Connections ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10221_20210519 O&M_AP2000_10084_20210519 - 11...
  • Page 14: Maintenance

    If these recommendations are not followed, the AP Unit will cause thin ice several meters around the vicinity, creating a very large hazardous area. ©2021 IXOM Watercare Inc. | www.ixomwatercare.com | 866 - 437 - 8076 | watercare@ixom.com 10088_20210430 O&M_AP2000_10084_20210519 - 12...
  • Page 15: Technical Data Sheet

    ® steel with a durable clog-free design and no moving parts for low maintenance. The AP2000 stays out of sight but allows for mixing of small ponds and lake with no part of the machine above the water. Specifically designed for small ponds and docks.
  • Page 16: Warranty

    Where labor is included, in lieu of sending a factory service crew to the site for minor repairs, Ixom may choose to send the replacement parts to the owner postage-paid and may pay the owner a reasonable labor allowance, as determined solely by Ixom, to install the parts.
  • Page 17: Customer Service

    © Distribution Treatment, Wastewater Treatment and Lakes & Source Water Reservoirs. IXOM has thousands of installations and is an industry-leader solving water quality problems across the United States, Canada and the world. Contact us today to discuss your water quality and service needs.

Table of Contents