Adjustable Parameters - Scania Interlock 7000 Instructions For Use Manual

Breath alcohol measuring instrument
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20

Adjustable parameters

Power consumption
Maximum
Stand-by
Switch relay for the lead for the
starter relay
Output relay
switchable de-energized
switchable energized
Ignition lead
Waiting time to ready for
measurement
20 °C
0 °C
-25 °C
-45 °C
34
<2.5 A
<1 mA
<16 A, continuous
<40 A, peak
48 V
24 V
5 V to 48 V
Interlock 5000
Interlock 7000
7 s
2 s
15 s
<5 s
<60 s
<60 s
<115 s
110 s
9
Adjustable parameters
Some instrument parameters may be set differently by a Dräger
Interlock service centre due to legal regulations in different countries
or individually during installation.
The descriptions of these Instructions for Use are related to the
basic version.
Table of essential adjustable parameters:
Parameter
Operation
Display of test result
Breath test volume
Limit value (initial test)
Restart period
Data storage
Data storage
Service
Calibration interval
Possible to start engine after the end of
the service interval
Retests
Retests (whilst the vehicle is in use)
Basic version
Test passed /
Test failed
1.0 litre
0.30 ‰ or 0.20 ‰
30 minutes
On
365 days
Yes
No
Dräger Interlock 7000